Recommendations Concerning Materials and Pumping Systems Used in the Sampling of Groundwater Contaminated with Volatile Organics

Author:

Devlin J.F.1

Affiliation:

1. Water and Earth Science Associates, Box 430, Carp, Ontario, Canada K0A 1L0

Abstract

Abstract Laboratory and field studies were performed at the River Road Laboratories of Environment Canada, to evaluate the effect of storage containers, tubing material and pumping method on the integrity of groundwater samples contaminated with volatile organics. The work was aimed at establishing a sampling protocol which can be easily adapted to a variety of field situations and which preserves sample integrity at every stage from collection to analysis. In the laboratory, storability studies were conducted on prepared samples containing a suite of 15 volatile aliphatic, halogenated aliphatic and aromatic compounds, in both glass vials and in Tedlar bags developed during the project. Glass was found to be the preferred container for the storability of samples. Leaching studies were carried out on both Teflon and polyethylene tubing (100 ft., 0.2″ i.d.); neither material was found to substantially contaminate organic-free deionized water. Sorption studies conducted on the same tubing sample 9 indicated that polyethylene sorbs the organics to a substantially greater degree than Teflon. However, representative samples can be obtained through both tubing materials provided that a flushing procedure is followed prior to sample collection. In the field, tests were carried out to determine if sampling into glass vials (significant sample/air contact during collection) introduces any bias to prepared standards. The results suggest that a closed sampling system is preferred. However, all vial samples were collected without analytically significant losses of volatiles. Tubing performance was tested at specially designed piezometers constructed so that groundwater samples could be collected from the same place through either polyethylene or Teflon tubing. It was determined that quantitatively similar samples can be collected through both types of tubing. A comparative study between peristaltic and positive displacement pumping methods was undertaken. The Teflon bladder pump (no air contact) was judged superior overall. Peristaltic suction did not appear to bias samples substantially, however, the condition of the piezometer did have a significant effect on sample representivity.

Publisher

IWA Publishing

Subject

Water Science and Technology

Cited by 11 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Can groundwater sampling techniques used in monitoring wells influence methane concentrations and isotopes?;Environmental Monitoring and Assessment;2018-03-06

2. Effect of magnetic water treatment on calcium carbonate precipitation: Influence of the pipe material;Chemical Engineering and Processing: Process Intensification;2009-08

3. Purging and Sampling Device Selection and Operation;The Essential Handbook of Ground-Water Sampling;2006-11-27

4. Use of Direct-Push Technologies in Environmental Site Characterization and Ground-Water Monitoring;Practical Handbook of Environmental Site Characterization and Ground-Water Monitoring, Second Edition;2005-09-28

5. Ground-Water Sampling;Practical Handbook of Environmental Site Characterization and Ground-Water Monitoring, Second Edition;2005-09-28

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3