Affiliation:
1. Swedish Institute of Agricultural and Environmental Engineering, PO Box 7033, SE-750 07 Uppsala, Sweden
Abstract
An anaerobic digester (8 l) was fed with the organic fraction of municipal solid waste and monitored intermittently for two years with on-line near-infrared (NIR) spectroscopy and traditional chemical parameters analysed off-line. The dynamics that occurred due to changes in substrate composition (changed C:N ratio) and changes in operating conditions (overloading) could be followed using principal component analysis of the obtained NIR-spectra. In addition, process disturbances such as failed stirring and increased foaming were readily detected by the NIR-spectra. Using PLS regression the propionate concentration could be predicted in the range 0.1-3.6 g/l, RMSEP 0.53 g/l with slope 0.74 and correlation coefficient 0.85. The response on changes in the digester fluid was reproducible and could be detected within 2.5 minutes, which can be considered as real-time monitoring.
Subject
Water Science and Technology,Environmental Engineering
Cited by
31 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献