Detection of Naegleria spp. and Naegleria fowleri: a comparison of flagellation tests, ELISA and PCR

Author:

Behets J.1,Seghi F.1,Declerck P.1,Verelst L.2,Duvivier L.2,Van Damme A.3,Ollevier F.1

Affiliation:

1. Laboratory of Aquatic Ecology, Catholic University Leuven, Ch. De Beriostraat 32, B-3000 Leuven, Belgium

2. LABORELEC, Rodestraat 125, 1630 Linkebeek, Belgium

3. ELECTRABEL, Rodestraat 125, 1630 Linkebeek, Belgium

Abstract

To detect Naegleria spp, in particular Naegleria fowleri, the causative agent of human primary amoebic meningoencephalitis, a flagellation test (FT) is routinely used followed by a specific ELISA. A positive FT indicates the presence of Naegleria spp although some false negatives are likely to occur since parameters for enflagellation vary greatly. As negative FTs are not routinely screened any further for the presence of N. fowleri, this could result in an underestimation of the presence of this pathogen. Therefore, amoebae were further analysed using ELISA and standard PCR not only after a positive but also after a negative FT. In this study 39 cultures containing amoebae were tested with FT, ELISA and the two PCR assays with 11 positive for FT. These were submitted to ELISA and four confirmed as N. fowleri. PCR with the common primer-set on these 11 positive FTs revealed all as Naegleria spp. The specific PCR used on these cultures detected four positive for N. fowleri, corresponding totally with the ELISA results. The 28 negative flagellation tests were also submitted to ELISA and PCR. Of these, 11 were identified as Naegleria spp with common PCR and six as N. fowleri as well as with ELISA and the specific PCR. When the detection of Naegleria spp is based on intermediary processes, such as flagellation tests, false negatives are likely to occur leading to severe underestimations. This study has shown that amoebae taken from negative FTs can be identified as Naegleria spp and N. fowleri when using PCR and ELISA. The application of at least one of the specific N. fowleri tests is recommended for routine screening. The heterogeneous distribution of the false negative results between the different power plants suggested the presence of different genotypes.

Publisher

IWA Publishing

Subject

Water Science and Technology,Environmental Engineering

Cited by 30 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3