Pilot-scale demonstration of the hybrid zero-valent iron process for treating flue-gas-desulfurization wastewater: Part I

Author:

Huang Yong H.1,Peddi Phani K.1,Zeng Hui1,Tang Ci-Lai1,Teng Xinjun2

Affiliation:

1. Department of Biological and Agricultural Engineering, Texas A&M University, TAMU 2117, College Station, TX 77843, USA

2. Southern Company, 600 18th Street North, Birmingham, AL 35291, USA

Abstract

The hybrid zero-valent-iron (hZVI) process is a novel chemical treatment process that has shown great potential in previous laboratory and field bench-top scale tests for removing selenium, mercury and nutrients from various industrial wastewaters. In this study, a pilot-scale demonstration was conducted to continuously treat 3.8–7.6 L/min (1–2 gpm) of the flue-gas-desulfurization (FGD) wastewater at a coal-fired power plant for five months. Results show that the hZVI process could simultaneously reduce selenate-Se from 1 to 3 mg/L to below 10 μg/L and mercury from over 100 μg/L to below 10 ng/L in compliance with the new stringent effluent discharge limits planned by the U.S. EPA for Se and Hg. A three-stage hZVI system with a combined hydraulic retention time of 12 h is sufficient for Se treatment, while a single-stage system can meet Hg treatment requirement. The successful pilot study demonstrated that the hZVI process is scalable and could be a reliable, low-cost, high-performance treatment platform with many application potentials, particularly, for solving some of the toughest heavy metal water problems.

Publisher

IWA Publishing

Subject

Water Science and Technology,Environmental Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3