Affiliation:
1. Colifast AS, PO Box 31, N-1324 Lysaker, Norway
2. Gothenburg Water and Sewage Works, Box 123, S-42423 Angered, Sweden
Abstract
There is a recognised need for methods that permit rapid estimation of the sanitary quality of water e.g. during raw water monitoring and emergencies involving water treatment failure or main breaks in a distribution network. In this study, two models for predicting the level of faecal contamination of water were studied. The first format, based on measurement of b-galactosidase activity by the automated Colifast analyser, detected faecal contamination of high levels, corresponding to >15 thermotolerant coliforms (FC)/5 mL, in 1-3 h, in a format that allowed for semi-quantification of results. By setting up a cut-off level, the system could be used as an operational tool identifying random increases in faecal contamination during routine raw water monitoring. A second Presence-Absence format was dependent upon the growth of low levels of FC with subsequent detection in the Colifast analyser. 95% of water samples containing 1-15 FC/sample volume showed positive detection after 11 h.
Subject
Water Science and Technology,Environmental Engineering
Cited by
9 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献