Affiliation:
1. Natural Resources Research Institute, University of Minnesota, 5013 Miller Trunk Highway, Duluth, MN 55811, USA
Abstract
Approximately 30% of Minnesotans use on-site systems (~500,000 residences) and >50% are failing or non-compliant with regulations due to restrictive soils and site conditions. Many sites occur near lakes and streams creating health hazards and deteriorating water quality. SSF CWs have been evaluated year-round at two northern sites since 1995. The NERCC CWs simulate single homes and the Grand Lake demonstration CW treats STE from a cluster of 9 lakeshore homes. Systems were generally able to achieve design criteria of 25 mgTSS/L and 30 mgBOD5/L and the NERCC CWs required only 0.3m of unsaturated soil to achieve consistent disinfection to <200 fecals/100 mL year round. Seeding experiments with Salmonella indicated removal efficiencies of 99.8% in summer and 95% in winter. High strength (∼300 mgBOD/L, 95 mgTN/L) influent at NERCC probably limited system performance, particularly N-removal (mass) which was ∼42% in summer and 20% in winter. The data indicate CW's are a viable, year-round treatment option for homeowners in terms of performance, ease of operation, and cost but require additional maintenance related to inconsistent vegetation growth, winter insulation, and meeting concentration-based regulatory standards since they were seasonally and annually variable due to rain events, partial freezing, spring snowmelt, and summer evapotranspiration.
Subject
Water Science and Technology,Environmental Engineering
Cited by
9 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献