Affiliation:
1. Faculty of Engineering and Surveying, University of Southern Queensland, West Street, Toowoomba 4350, Australia
Abstract
As stormwater flows are intermittent, the requirement to store urban runoff is important to the design of a stormwater re-use scheme. In many urban areas, the space available to provide storage is limited and thus the need to optimise the storage volume becomes critical. This paper will highlight the advantages and disadvantages of two different approaches of providing storage: 1) a single shallow storage (0.5 m depth) in which stormwater capture and a balanced release to supply users is provided by the one unit; and 2) a dual system in which the functions of stormwater capture and supply release are provided by two separate deeper storage units (2 m depth). The comparison between the two strategies is supported by water balance modelling assessing the supply reliability and storage volume requirements for both options. Above a critical volumetric capacity, the supply yield of a dual storage system is higher than that from a single storage of equal volume mainly because of a smaller assumed footprint. The single storage exhibited greater evaporation loss and is more susceptible to algae blooms due to long water residence times. Results of the comparison provide guidance to the design of more efficient storages associated with stormwater harvesting systems.
Subject
Water Science and Technology,Environmental Engineering
Cited by
19 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献