Affiliation:
1. a China Sri Lanka Joint Research and Demonstration Centre for Water Technology, Ministry of Water Supply, Kandy, Sri Lanka
2. b National Water Supply and Drainage Board, Puttam, Sri Lanka
3. c Uva Wellassa University, Badulla, Sri Lanka
Abstract
Abstract
This study was conducted to investigate the effect of different in-house practices on trihalomethane (THM) level fluctuations in pipe-borne water. Common in-house practices such as boiling, unboiling, boiling water with headspace/non-headspace, storage vessels materials, storage practices, and storage time were investigated to study residual THM and their percentage. Vessels made of plastic (P), clay (C), stainless steel (SS), glass (G), and aluminium (Al) were used for the study. Prime trihalomethanes of CHCl3, CHBrCl2, CHBr2Cl, CHBr3, and total of those four THMs (TTHMs) were measured, and removal/formation percentages were calculated. Results revealed that the percent change of TTHM varies based on the boiling practice as follows: open boiling TTHM > close boiling with headspace TTHM > close boiling without headspace (CBWH) TTHM. The following order was observed for residual TTHM for 6 h storage in the vessels; for CBWH water storage in open vessels C < G < P < SS < Al and close vessels C < G < P < SS < Al; and for unboiled water storage in open vessels SS < C < Al < P < G and close vessels C < P < Al < SS < G. In conclusion, the lowest concentration of residual TTHM was found in the boiled water stored in a clay pot and recommended as an in-house practice to reduce TTHM.
Subject
Water Science and Technology
Cited by
1 articles.
订阅此论文施引文献