Affiliation:
1. Takeda Chemical Industries Ltd., 2-17-85, Juso-Honmachi, Yodogawa-ku, Osaka, Japan
2. Department of Environmental Engineering, Osaka University, 2-1, Yamada-Oka, Suita, Osaka, Japan
Abstract
Six kinds of enzyme-linked immunosorbent assay (ELISA) systems were developed for the quantitative analysis of hormone-disrupting chemicals (HDCs), such as estrogen (ES: the total amount of estrone (E1), 17 β-estra (E2) and estriol (E3)), E2, bisphenol A (BPA), alkylphenol (AP), phthalate esters (PE) and chlorophenols (CP). To generate specific monoclonal antibodies against BPA, AP, PE, CP, hybridoma cells were produced by the fusion of mouse myeloma cells and spleen cells from mice immunized with carboxylated derivatives, while anti E2 monoclonal antibody was selected from those available on the market, and anti ES monoclonal antibody was purchased from Teikoku Hormone Mfg Co. Ltd. The detection limits of ES, E2, BPA, AP, PE and CP ELISAs were 0.1, 0.1, 5, 10, 200, 10 μg/L, when E2, E2, BPA, Nonylphenol (NP), Dibutylphthalate (DBP), 2,4-CP were used as standard, respectively, and the specificity of each ELISA was confirmed with the cross-reaction test using several compounds which have structural resemblance to the compounds of interest.
Subject
Water Science and Technology,Environmental Engineering
Cited by
57 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献