Author:
Tai Hak Chung,Doo Yeon Kim
Abstract
An experimental study was conducted to identify the effect of each operating variable on the liquid-solids separation efficiency using a bench scale batch flotation system and waste activated sludge. Interpretation of the experimental results was performed by use of the characteristic constants of an empirical equation proposed. Minimum A/S ratio for reliable operation of dissolved air flotation should be greater than 0.009. However, unstable sludge rising took place at the initial clarification stage due to excessive shear and turbulence when the pressure was high in spite of high A/S ratio. The efficiency increased as the A/S ratio increased except a case of high pressure coupled with high A/S ratio. High recirculation flow with a saturator pressure less than 5 atm is recommended for stable and efficient operation. The pore size of a diffuser did not affect the thickening efficiency significantly. Concentration gradient of the float solids became larger as flotation continued. Skimming of a top layer or a long skimming interval is desirable for high thickening efficiency.
Subject
Water Science and Technology,Environmental Engineering
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献