Comparison of Analytical Techniques for Analysis of Arsenic Adsorbed on Carbon

Author:

Yadav Nirbhay Narayan1,Maheswaran Saravanamuthu1,Shutthanandan Vaithiyalingam2,Thevuthasan Suntharampillai2,Hart Todd R.2,Ngo Huu Hao3,Vigneswaran Saravanamuthu3

Affiliation:

1. Nanoscale Organisation and Dynamics Group, University of Western Sydney, Penrith South DC, NSW 1797, Australia

2. Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, Washington, 99352, United States

3. Faculty of Engineering, University of Technology - Sydney, Sydney, NSW 2007, Australia

Abstract

Abstract Activated carbon (AC) has been used extensively to treat arsenic-contaminated groundwater for a number of years. To date, attempts to quantify directly the amount of arsenic removed by the activated carbon using nondestructive methods has been limited. High-energy ion beam based proton induced x-ray emission (PIXE) is ideally suited to investigate the issues regarding the quantification of trace metals in solids. In this study, after the adsorption of arsenic on activated carbon, arsenic concentration in granular activated carbon (GAC) and powder activated carbon (PAC) were quantified using PIXE. The PIXE results were compared with atomic absorption spectrometry (AAS) and inductively coupled plasma optical emission spectrometry (ICP-OES) measurements. Some differences are observed between these measurements. The differences are greater in the case of GAC compared to PAC. These differences are mainly due to the inhomogeneous structure of GAC and PAC, which includes the variable surface properties such as surface area and pore sizes in each granule or particle. The larger differences are mainly due to the increased particle dimensions of GAC compared to PAC and the nature of the internal pore structure of GAC, which results in different amounts of arsenic adsorbed on different granules of GAC or even in different regions of one granule. This inhomogeneity of arsenic concentration is clearly visible in the arsenic concentration map generated for a single GAC particle using microbeam PIXE.

Publisher

IWA Publishing

Subject

Water Science and Technology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3