An evaluation of a new rapid qPCR test for the detection of 2019-novel coronavirus nucleocapsid (N1) gene in wastewater in Roanoke and Salem VA sewersheds

Author:

Lehrer Lia Willow1ORCID,Lewis Anna Marie1ORCID,Tolliver Susan2ORCID,Degen Marcia3ORCID,Singh Rekha3,Houser Sara1ORCID,Rao Jayasimha2456ORCID

Affiliation:

1. a Radford University Carilion (RUC), Roanoke, VA, USA

2. b Carilion Roanoke Community Hospital, Carilion Clinic Basic Science Research Lab (BSRL), Roanoke, VA, USA

3. c Virginia Department of Health (VDH), Richmond, VA, USA

4. d Internal Medicine, Division of Infectious Disease, Carilion Medical Center, Roanoke, VA, USA

5. e Center for Emerging, Zoonotic, and Arthropod-borne Pathogens, Virginia Tech, Blacksburg, VA, USA

6. f Translational Biology, Medicine, and Health, Virginia Tech, Roanoke, VA, USA

Abstract

ABSTRACT The COVID-19 pandemic initiated public interest in wastewater-based epidemiology (WBE). Public and private entities responded to the need to produce timely and accurate data. LuminUltra and Hach partnered to provide a rapid, field-based quantitative polymerase chain reaction (qPCR) test for detecting severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in wastewater. This study evaluates the Hach GeneCount SARS-CoV-2 Wastewater RT-qPCR Assay Kit and LuminUltra GeneCount® Q-16 RT-PCR instrument. The Hach LuminUltra methods were compared to the Promega Wizard® Enviro Total Nucleic Acid kit and Bio-Rad CFX Opus 96 Real-time PCR Detection System. Over a 12-week period, wastewater samples were collected weekly from seven locations in the Roanoke/Salem, VA sewersheds. Concentration and extraction of the viral RNA were followed by qPCR analysis. The target gene for detection was the nucleocapsid gene (N1) of the SARS-CoV-2 virus. Costs, ease of use, time to produce results, sample preparation, and data comparisons were considered. The comparison determined that the Hach LuminUltra method and instrument were more affordable, consumed less time, and required less technical expertise. While the new method was specific, it had low sensitivity. This evaluation suggests the Hach LuminUltra method should be reserved for limited situations requiring onsite field analysis where data accuracy is not essential.

Funder

Centers for Disease Control and Prevention Foundation

Virginia Department of Health

Publisher

IWA Publishing

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3