Features of the integration of two-layer metal knitwear made of titanium nickelide during the replacement of a thoracoabdominal defect in the experiment

Author:

Topolnitskiy E. B.1ORCID,Shefer N. A.2ORCID,Marchenko E. S.3ORCID,Fomina T. I.4ORCID,Mikhed R. A.2ORCID,Tsydenova А. N.2ORCID,Garin A. S.3ORCID

Affiliation:

1. Siberian State Medical University; National Research Tomsk State University

2. Siberian State Medical University

3. National Research Tomsk State University

4. Goldberg Research Institute of Pharmacology and Regenerative Medicine, Tomsk National Research Medical Center, Russian Academy of Sciences

Abstract

The aim of investigation was to study experimentally the morphological features of tissue integration of two-layer titanium nickelide (TiNi) knitwear when replacing thoracoabdominal defects.Materials and methods. The experiments were carried out on 40 Wistar rats. The experimental animals were divided into two comparison groups: in Group A (n = 20) the defect was replaced using a two-layer knitted tape made of TiNi, in Group B (n = 20) a polypropylene mesh implant was used. The technique of the operation and the peculiarities of keeping the animals did not differ. Animals were taken out after 14, 30, 60 and 90 days of experiment. The macroscopic structural features at the site of implant fixation to tissues and at the sites of contact with underlying organs were studied, and the inflammatory process was assessed. The histological and electron microscopic study was carried out with an assessment of the features of tissue integration through the mesh structure of knitwear.Results. Thirty days after the surgery in four cases of Group B the appearance of the chest wall deformation at the site of implant fixation was noted, in one case the deformation site was located along the lateral edge of the abdominal wall. Among the animals of Group A no such changes were recorded. The histological and electron microscopy examination revealed that the porous structure of the TiNi wire, as well as the biomechanical and biochemical properties of the two-layer metal knitwear, ensure optimal integration of the endoprosthesis in the body tissues, forming an elastic frame close to natural. In Group B, on the contrary, the reaction of the body caused by the implanted polypropylene prosthesis was characterized by more pronounced fibrosis, and tissue integration through the mesh structure of the implant was not observed.Conclusion. Two-layer TiNi knitwear in the replacement of complex structures of the thoracoabdominal zone showed promising results, which opens up prospects for further clinical research.

Publisher

FSPSI SCFHHRP

Subject

General Immunology and Microbiology,General Biochemistry, Genetics and Molecular Biology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3