Changes in Indicators of Microcirculation in the Early Postoperative Period in the Treatment of Diaphyseal Fractures of the Shin Bones Using a Plate with Limited Contact

Author:

Plakhov A. I.1,Kolesnikova L. I.2,Korytov L. I.1,Vinogradov V. G.1,Darenskaya M. A.2

Affiliation:

1. Irkutsk State Medical University

2. Scientific Centre for Family Health and Human Reproduction Problems

Abstract

Background. Unsatisfactory results of treatment, such as delayed consolidation and non-fusion of fractures, the formation of false joints and limb bone defects, have no tendency to decrease. We can assume that one of the leading factors of complications in traumatology is a violation of microcirculation in the affected segment of the limb.Aims. To identify patterns of changes in the parameters of the microcirculatory bed of the damaged segment of the lower limb when fixing bone fragments with a plate with limited contact in the early period after surgery.Materials and methods. In 25 patients, we studied four parameters of microcirculation of the lower limb segment with application of laser Doppler flowmetry. The control group consisted of 25 healthy volunteers, comparable in age and sex with the study group.Results. We found that in the early postoperative period (from the first to the 10th day after the surgery) in patients with diaphyseal fractures of the tibia operated with metal plate with limited contact there was an increase in microcirculation by 75.69 %, an increase in the proportion of the nutritive component of microcirculation compared to the shunt fraction by 24.64 %, as well as an increase in more than one ratio of the amplitude of the heart and respiratory range. All of that indicates a local circulatory disorder in the nutritive arterial hyperemia. We note that the increase in the amplitude of the respiratory component by 17.22 % and the equality of the amplitude of the cardiac range compared with the control group indicate violations of local blood circulation by the type of venous stagnation.Conclusion. On the basis of the results obtained, we note that patients with diaphyseal fractures of the shin bones treated with metal osteosynthesis with a plate with limited contact in the early postoperative period develop a violation of local blood circulation in the stagnant-hyperemic type.

Publisher

FSPSI SCFHHRP

Subject

General Immunology and Microbiology,General Biochemistry, Genetics and Molecular Biology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3