Assessment of Inter-Instrument Reliability for Dominant Handgrip Dynamometry and Spirometry

Author:

Mgbemena Nnamdi,Jones Anne,Leicht Anthony

Abstract

Purpose: The aim of this study was to determine the inter-instrument reliability of different dynamometers and spirometers commonly used in clinical practice. Methods: The study involved 113 healthy volunteers across three facility sites. At each site, dominant handgrip strength (DHGS), and lung function (forced expiratory volume in one second [FEV1], forced vital capacity [FVC] and peak expiratory flow rate [PEFR]), were compared using a local and reference device. Assessments were randomized with five minutes rest between measurements. Significant differences between devices were assessed using paired t-test while relative reliability between devices was determined via intra-class correlations (ICC). Accuracy index and variability between measurements were assessed using the technical error of measurement (TEM%) and coefficient of variation (CV), respectively. Agreement between devices was determined using the Bland Altman’s plot with limits of agreement (LOA). Results: The local devices recorded significantly (p1 (3.1%-8.4%), FVC (3.1%-13%) compared to the reference devices. Good-excellent correlations (ICC=0.89-0.96), unacceptable CV (5.8-9.9%) and TEM% (6.6-9.9%), and large mean biases (3-9kg) and LOA (3-23kg) were identified between the local and reference dynamometers. Excellent correlations (ICC=0.91-0.99), and mostly unacceptable CV and TEM% were identified between the local and reference spirometers for FVC and PEFR. Compared to the reference device, all local spirometers showed unacceptable (-0.134 to -0.536 liters) and acceptable (-0.12 to 0.05 liters/second) mean biases for FVC and PEFR, respectively. Conclusion: Unacceptable inter-instrument reliability was identified between local and reference dynamometers and spirometers for measuring DHGS and all lung function indices, respectively. Across clinical settings, comparing DHGS and lung function between different brands of devices may lead to the reporting of erroneous results with corrective adjustments required for clinical practice.

Publisher

Nova Southeastern University

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3