Affiliation:
1. DICLE UNIVERSITY, FACULTY OF DENTISTRY
2. İSTANBUL SAĞLIK VE TEKNOLOJİ ÜNİVERSİTESİ
3. FIRAT UNIVERSITY, FACULTY OF DENTISTRY
Abstract
Aims: This study aimed to compare the shaping ability of T-endo MIS and TruNatomy (TRN) file systems in J-shaped resin root canals and to investigate the deformation of the files after two acrylic block preparation and two sterilization cycles. Methods: Forty acrylic blocks were numbered, then four file groups (n=10) were established: T-endo MIS glider (15.04) + T-endo MIS Finisher (25.04) (first and second usage) and TRN Glider (17.02) + TRN Prime (26.04) (first and second usage). Preoperative and postoperative images after the root canal preparation of simulated acrylic blocks were taken for each sample, and superimposed. The amount of resin removed from both the inner and outer walls of the canal to the level of 3, 5, and 7 mm from the apical point was measured, and the amount of transportation was calculated. Additionally, the deformation of the files was examined under a scanning electron microscope before and after usage and sterilization process. Results: Tip deformation of TRN files increased with the number of uses (p=0.007). With the second use, the surface deformation of the MIS files increased (p=0.015). There was no difference in cutting-edge deformation in either file type according to the number of uses (p>0.05). There was no difference in transportation values between the MIS and TRN file systems at any level (p>0.05). The file systems did not show a significant difference in the amount of transportation between first and second use (p>0.05). Conclusion: When TRN (26.04) and MIS (25.04) NiTi rotary files were used twice on acrylic blocks, the amount of deformation did not differ. Both file types were similar in terms of transportation values.
Publisher
Journal of Health Sciences and Medicine
Subject
General Earth and Planetary Sciences,General Environmental Science
Reference35 articles.
1. Haikel Y, Serfaty R, Bateman G, Senger B, Allemann C. Dynamic and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instruments. J Endod. 1999;25:434-440.
2. Yang Y, Hou B, Hou X. Effect of autoclave on surface microstructure and cyclic fatigue resistance of R-phase rotary instruments. J Peking Univ Health Sci. 2018;50:882-886.
3. Ounsi HF, Franciosi G, Paragliola R, Goracci C, Grandini S. Effect of repeated use on the shaping ability of Protaper Universal rotary files. Int Dent SA. 2010;12:30-35.
4. Armagan S, Haznedaroglu F. Scanning electron microscopy analysis of conventional and controlled‐memory nickel titanium files before and after multi‐uses in root canals. Micros Res Tech. 2021;84:1321-1327.
5. Valois CR, Silva LP, Azevedo RB. Multiple autoclave cycles affect the surface of rotary nickel-titanium files: an atomic force microscopy study. J Endod. 2008;34:859-862.