Coated vs Uncoated Implants: Bone Defect Configurations After Progressive Peri-implantitis in Dogs

Author:

Madi Marwa1,Zakaria Osama2,Kasugai Shohei2

Affiliation:

1. Department of Oral Implantology and Regenerative Dental Medicine, Tokyo Medical and Dental University, and Global Center of Excellence (GCOE), Tokyo Medical and Dental University, Tokyo, Japan.

2. Department of Oral Implantology and Regenerative Dental Medicine, Tokyo Medical and Dental University

Abstract

In this study, hydroxyapatite coated vs uncoated implants were used to evaluate the type and dimensions of bone defects after progressive peri-implantitis in dogs. Thirty-two dental implants with 4 different surfaces—machined (M), sandblasted acid-etched (SA), 1-μm thin sputter hydroxyapatite (HA)-coated (S), and plasma-sprayed HA-coated (P)—were inserted into the mandibles of 4 beagle dogs after extracting all mandibular premolars. Experimental peri-implantitis was induced after 3 months using ligature to allow for plaque accumulation. After 4 months, ligatures were removed and plaque accumulation continued for 5 months (progression period). The open flap surgery demonstrated 3 patterns of peri-implantitis bone defect: (1) Class I defect: represented as circumferential intra-alveolar bone loss; (2) Class II defect: circumferential intra-alveolar defect with supra-alveolar bone loss exposing the implant surface; and (3) Class III defect: represented as circumferential intra-alveolar defect with supra-alveolar bone loss and buccal dehiscence. Class I was the most frequent (62.5%) defect pattern around implant types M, SA, and S; while implant type-P showed a recurring majority of Class II (62.5%). Comparison among the 4 implant groups revealed a significant defect width (DW) in implant type-P relative to other types (P < 0.01). However, no statistically significant differences were noted for defect depth (DD) (P > 0.05). We concluded that the shape and size of peri-implantitis bone defects were influenced by the type and thickness of the HA coat together with the quantity of the available peri-implant bone. Plasma-sprayed HA-coated implants showed larger peri-implant defects than did thin sputter HA-coated implants.

Publisher

American Academy of Implant Dentistry

Subject

Oral Surgery

Cited by 16 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3