Influence of Abutment Screw Design and Surface Coating on the Bending Flexural Strength of the Implant Set

Author:

Prado Célio Jesus do1,Neves Flávio Domingues das1,Soares Carlos José2,Dantas Kelly Abadia1,Dantas Talita Souza3,Naves Lucas Zago4

Affiliation:

1. Department of Occlusion, Fixed Prosthodontics, and Dental Materials, School of Dentistry, Federal University of Uberlandia, Uberlandia, MG, Brazil.

2. Department of Operative Dentistry and Dental Materials, School of Dentistry, Federal University of Uberlandia, Uberlandia, MG, Brazil.

3. Oral Rehabilitation Program, School of Dentistry, Federal University of Uberlandia, Uberlandia, MG, Brazil.

4. Department of Restorative Dentistry, Dental Materials Division, Piracicaba Dental School, University of Campinas–UNICAMP, Piracicaba, SP, Brazil.

Abstract

The purpose of this study was to analyze the influence of the setting and the presence of solid lubricant on the abutment screw surface on the flexural strength of the joint implant/abutment/screw. Forty abutments were connected to external hex implants, divided into 4 groups (n = 10): FE (titanium alloy screw threaded in the extremity), LE (titanium alloy screw with solid lubricant and thread in the extremity), FT (titanium alloy screw with threaded in all its length), and LT (titanium alloy screw with solid lubricant and thread in all its length). Through the mechanical flexural test, the implant/abutment resistance was evaluated with load applied perpendicular to the long axis in a mechanical testing machine (EMIC) under a speed of 0.5 mm/min. Data were submitted to a statistics test, and results showed statistically significant differences between the FE group and the other groups, and the FE group showed the lowest values. The LE group showed greater values than the LT group, and the values were statistically significant. According to the methodology used, it can be concluded that within noncoated titanium screws, a screw threaded along its entire length provided greater rigidity to the implant set, while with the screw containing solid lubricant, the screw threaded in all its length provided less rigidity of the implant set than screws with the thread only on the end. Among screws with the same geometry, those with the solid lubricant are statistically higher than those which do not have threads just at the end, but those with threads along their entire length do not show statistically significant differences.

Publisher

American Academy of Implant Dentistry

Subject

Oral Surgery

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3