Retention of Implant-Supported Overdenture With Bar/Clip and Stud Attachment Designs

Author:

Savabi Omid1,Nejatidanesh Farahnaz2,Yordshahian Forough3

Affiliation:

1. Torabinejad Dental Research Center, Department of Prosthodontics, School of Dentistry, Isfahan University of Medical Sciences; Biomaterials Research Group, Isfahan University of Technology Isfahan, Iran.

2. Dental Materials Research Center, Department of Prosthodontics, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran.

3. School of Dentistry, Isfahan Islamic Azad University, Isfahan, Iran.

Abstract

The degree of retention for overdenture attachments depends on design, location, and alignment of supporting dental implants and the type of attachments. The aim of this study was to evaluate the retention of an implant-supported overdenture with different attachment designs. An overdenture was made on an edentulous mandibular model with 2 ITI implants (4.1 × 10 mm) in the symphyseal region. Five specimens of 8 attachment designs with corresponding abutments and superstructures were used: ITI regular Dolder bar with 1 metal clip, ITI regular Dolder bar with cantilever and 3 metal clips, Hader bar with 1 plastic clip, Hader bar with cantilever and 3 plastic clips, Sphero block abutment with Rhein plastic caps (green, white, and pink), and retentive anchor with ITI elliptical matrix. The attachments' housings were interchangeable and fixed into the overdenture through nut and screw. The overdenture attachments were subjected to 8 consecutive pulls on a universal testing machine with a crosshead speed of 50.8 mm/min in the vertical and posteroanterior directions. Analysis of variance and Duncan tests were used to determine differences between mean retention values (α = .05). The highest average value retention was recorded for the ITI Dolder bar with cantilever and 3 metal clips in both the vertical and posteroanterior directions, respectively (P < .05). The Rhein pink caps had the lowest retention in the posteroanterior direction (P < .05). Retention decreased over the course of consecutive pulls for all attachments in both directions. The type, number, and placement of attachments affect the retention of implant-supported mandibular overdentures.

Publisher

American Academy of Implant Dentistry

Subject

Oral Surgery

Cited by 26 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3