The Effect of Different Implant-Abutment Connections on Screw Joint Stability

Author:

Michalakis Konstantinos X.12,Calvani Pasquale (Lino)1,Muftu Sinan3,Pissiotis Argiris2,Hirayama Hiroshi1

Affiliation:

1. Division of Graduate and Postgraduate Prosthodontics, Tufts University School of Dental Medicine, Boston, Mass

2. Department of Removable Prosthodontics, Aristotle University of Thessaloniki, School of Dentistry, Thessaloniki, Greece

3. Northeastern University, Department of Mechanical and Industrial Engineering, Boston, Mass

Abstract

Dental implants with an internal connection have been designed to establish a better stress distribution when lateral external forces act on the prosthesis and minimize the forces transmitted to the fastening screw. In the present study, 10 externally and 10 internally hexed implants were tested with a compressive force applied with an Instron Universal machine. Four cycles of loading-unloading were applied to each specimen to achieve displacements of 0.5, 1, 2, and 2.5 mm. The mean loads for the first cycle were 256.70 N for the external connection and 256 N for the internal connection implants. The independent t test did not reveal any significant differences among the 2 tested groups (P = .780). For the second cycle, the mean loads needed for a displacement of 1 mm were 818.19 N and 780.20 N for the external connection and the internal connection implants, respectively. The independent t test revealed significant differences among the 2 tested groups (P < .001). In the third cycle, the mean load values for a 2-mm displacement were 1394.10 N and 1225.00 N. The independent t test revealed significant differences among the 2 tested groups (P < .001). The mean loads for the fourth cycle were 1488.00 N for the external connection and 1029.00 N for the internal connection implants. These loads were required for a displacement of 2.5 mm. The independent t test revealed significant differences among the 2 tested groups (P < .001). The results of this in vitro study suggest that the internal connection design of the examined implant system could not prevent screw loosening during overloading. No implant or prosthesis failure was noticed in either group.

Publisher

American Academy of Implant Dentistry

Subject

Oral Surgery

Cited by 27 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3