Resonance Frequency Analysis of 208 Straumann Dental Implants During the Healing Period

Author:

Guler Ahmet Umut1,Sumer Mahmut2,Duran Ibrahim3,Sandikci Elif Ozen2,Telcioglu Nazife Tuba2

Affiliation:

1. Department of Prosthodontics, Faculty of Dentistry, Istanbul Aydın University, Istanbul, Turkey.

2. Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Ondokuz Mayıs University, Samsun, Turkey.

3. Department of Prosthodontics, Faculty of Dentistry, Ondokuz Mayıs University, Samsun, Turkey.

Abstract

The most important prerequisite for the success of an osseointegrated dental implant is achievement and maintenance of implant stability. The aim of the study was to measure the 208 Straumann dental implant stability quotient (ISQ) values during the osseointegration period and determine the factors that affect implant stability. A total of 164 of the implants inserted were standard surface, and 44 of them were SLActive surface. To determine implant stability as ISQ values, measurements were performed at the stage of implant placement and healing periods by the Osstell mentor. The ISQ value ranges showed a significant increase during the healing period. Except for the initial measurement, the posterior maxilla had the lowest ISQ values, and there was no significant difference among anterior mandible, posterior mandible, and anterior maxilla (P < .05). Implant length did not have a significant influence on ISQ value (P > .05). The second measurement was significantly higher in men compared with women (P < .05). The second measurement was significantly higher than the others at 4.8 mm, and for the final measurement, there were no significant differences between 4.8 and 4.1 mm, which were higher than 3.3 mm (P < .05). When comparing sandblasted, large-grit, acid-etched (SLA) and SLActive surface implants, there were no significant differences for insertion measurements, but for second measurements, SLActive was significantly higher (P = 0), and for the final measurement, there was no significant difference. It appears that repeated ISQ measurements of a specific implant have some diagnostic benefit, and the factors that affect implant stability during the healing period are presented.

Publisher

American Academy of Implant Dentistry

Subject

Oral Surgery

Cited by 37 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3