This study investigated the marginal and internal fit and retention of crowns fabricated using 4 different castable pattern production methods, namely plastic burn out coping, computer-aided design and computer-aided manufacturing (CAD-CAM) milled (CAD-CAM-M), CAD-CAM additive (CAD-CAM-A), and conventional. This study consisted of 5 groups including 2 different brands of burn out coping groups (Burn out-Straumann [Burn out-S] group and Burn out-Implance [Burn out-I] group), the CAD-CAM-M group, the CAD-CAM-A group, and the conventional group. A total of 50 metal crown copings were produced in each group with 10 metal crown copings. The marginal gap of the specimens was measured twice—both before and after the cementation and thermocycling processes using a stereomicroscope. A total of 5 specimens were selected randomly—1 from each group for scanning electron microscopy analysis and sectioned longitudinally. The pull-out test was performed on the remaining 45 specimens. The lowest marginal gap value was observed in the Burn out-S group before and after cementation with 88.54–97.48 μm, respectively, while the highest marginal gap was observed in the conventional group (186.27–200.58 μm). Implant systems did not significantly affect the marginal gap values (P > .05). Marginal gap values increased significantly after cementation and thermal cycling in all the groups (P < .0001). The highest retention value was measured in the Burn out-S group while the lowest in the CAD-CAM-A group. The highest occlusal cement gap values were observed in the coping groups (Burn out-S and Burn out-I groups), and the lowest in the conventional group in the scanning electron microscopy analysis. The marginal fit and retention values of the prefabricated plastic burn out coping technique was superior when compared with the other techniques, providing that internal fit was superior with the conventional technique.
Publisher
American Academy of Implant Dentistry
Reference63 articles.
1. Sorensen
JA
.
A standardized method for determination of crown margin fidelity.
J Prosthet Dent.
1990;64:
18–24.
2. Jansen
VK
,
ConradsG,
RichterEJ.
Microbial leakage and marginal fit of the implant-abutment interface.
Int J Oral Maxillofac Implants.
1997;12:
527–540.
3. Jemt
T
.
In vivo measurements of precision of fit involving implant-supported prostheses in the edentulous jaw.
Int J Oral Maxillofac Implants.
1996;11:
151–158.
4. Di Felice
R
,
RappelliG,
CamaioniE,
CattaniM,
MeyerJM,
BelserUC.
Cementable implant crowns composed of cast superstructure frameworks luted to electroformed primary copings: an in vitro retention study.
Clin Oral Implants Res.
2007;18:
108–113.
5. Barbosa
GAS
,
Neves FDd, Mattos MdGCd, Rodrigues RCS, Ribeiro RF. Implant/abutment vertical misfit of one-piece cast frameworks made with different materials.
Braz Dent J.
2010;21:
515–519.
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献