The aim of this study was to evaluate primary stability of 3.7-mm diameter porous tantalum Trabecular Metal (TM) implant, and compare it to fully threaded implants, in the in vitro model of immediate implant placement in the anterior maxilla. A total of 60 implants were placed into bovine ribs using surgical guides. Implants were divided in 3 groups of 20 according to the design: TM, Tapered Screw-Vent (TSV), and NobelReplace. To simulate immediate placement in anterior maxilla, implants were placed under a sharp angle toward the ribs, not fully submerged. Placement angle of 20.7° was calculated after analysis of 148 virtually planned implants on cone beam computerized tomography scans of 40 patients. No statistically significant difference in implant stability quotient (ISQ) was found between TM (65.8 ± 2.6), TSV (64.7 ± 2.7), and NobelReplace (64.6 ± 2.7). TSV implants achieved higher insertion torque (37.0 ± 4.8 Ncm) than TM (32.9 ± 5.2 Ncm) and NobelReplace (23.2 ± 3.3 Ncm). TSV had the shortest insertion time of 13.5 ± 1.0 seconds, compared to 15.2 ± 1.2 seconds for TM, and 19.7 ± 1.7 seconds for NobelReplace. Pearson correlation analysis showed significantly correlated insertion torque and ISQ values for TM group (P = .011, r = .56), a nonsignificant correlation was found for TSV and NobelReplace. The results of the present study indicate that TM implant can achieve good primary implant stability in insertion torque and resonance frequency analysis.

Publisher

American Academy of Implant Dentistry

Subject

Oral Surgery

Reference34 articles.

1. Albrektsson T, Zarb GA. Current interpretations of the osseointegrated response: clinical significance. Int J Prosthodont. 1993; 6: 95– 105.

2. Bosshardt DD, Chappuis V, Buser D. Osseointegration of titanium, titanium alloy and zirconia dental implants: current knowledge and open questions. Periodontol 2000. 2017; 73: 22– 40.

3. Atsumi M, Park SH, Wang HL. Methods used to assess implant stability: current status. Int J Oral Maxillofac Implants. 2007; 22: 743– 754.

4. Degidi M, Daprile G, Piattelli A. Primary stability determination by means of insertion torque and RFA in a sample of 4,135 implants. Clin Implant Dent Relat Res. 2012; 14: 501– 507.

5. Levin BP. The correlation between immediate implant insertion torque and implant stability quotient. Int J Periodontics Restorative Dent. 2016; 36: 833– 840.

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3