Internal Hexagon vs Conical Implant–Abutment Connections: Evaluation of 3-Year Postloading Outcomes

Author:

Mihali Sorin Gheorghe1,Wang Hom-Lay2,Karancsi Olimpiu3,Bratu Emanuel Adrian3

Affiliation:

1. Department of Prosthodontics, Faculty of Dentistry, “Vasile Goldiş” Western University of Arad, Arad, Romania.

2. Department of Periodontics and Oral Medicine, University of Michigan School of Dentistry, Ann Arbor, Mich.

3. Department of Implant Supported Restorations, Faculty of Dentistry, Victor Babes University of Medicine and Pharmacy, Timisoara, Romania.

Abstract

Different types of internal implant–abutment connections, namely hexagon and conical, have been used for implant restoration. However, data regarding the benefits of these internal connections in terms of clinical outcomes are scarce. Accordingly, the aim of this study was to compare radiographic marginal bone loss (RMBL) and associated implant complications between implants with internal hexagon (IH) connections and those with internal conical (IC) connections. Forty-nine patients with 98 implants (2 per patient) placed in the posterior mandible were recruited. All implants were inserted in pairs into solid D2 bone according to a randomized sequence; the first patient received an IH connection implant on the mesial side, while the second patient received an IC connection implant on the mesial side. Each patient received 1 implant with an IH connection and 1 with an IC connection, placed side by side. Four months after placement, all implants were loaded with single screw-retained ceramic restorations with IH or IC connections. RMBL and complications, including implant/prosthesis failure, were recorded at the time of implant loading (baseline) and at 6, 12, and 36 months after loading. The results revealed no significant between-group differences in RMBL (P = .74), gingival bleeding on probing (P = .29), and complications (P = .32). Thus, the type of internal implant–abutment connection did not affect clinical outcomes, including RMBL and implant/prosthesis failure. Future studies should additionally evaluate long-term prosthesis-related complications, such as screw loosening and fracture, between the 2 types of internal connections.

Publisher

American Academy of Implant Dentistry

Subject

Oral Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3