Cleaning Efficacy of Poly-ether-ether-ketone Tips in Eliminating Cement Remnants Around Implants With Different Abutment Heights

Author:

Koyuncuoglu Cenker Zeki1,Kara Haluk Baris2,Akdemir Sinan3,Demir Becen4,Husain Nadin Al-Haj5,Özcan Mutlu16

Affiliation:

1. Department of Periodontology, Faculty of Dentistry, Istanbul Aydin University, Istanbul, Turkey.

2. Department of Proshtetic Dentistry, Faculty of Dentistry, Medipol University, Istanbul, Turkey.

3. Dental Prosthetics Technology Program, Health Sciences High School, Medipol University, Istanbul, Turkey.

4. Private practice, Istanbul, Turkey.

5. Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.

6. Division of Dental Biomaterials, Center for Dental and Oral Medicine, Clinic for Reconstructive Dentistry, University of Zurich, Zurich, Switzerland.

Abstract

The excess cement not removed after the cementation of fixed implant-supported restorations may cause loss of peri-implant attachment or adjacent bone. The aims of this study were to evaluate the amount of residual cement at different abutment-crown connection levels and to test the cleaning efficacy of poly-ether-ether-ketone (PEEK) ultrasonic tips after cementation. One implant was placed in an anterior central tooth position 5 mm below the gingival margin in an acrylic model, and 32 stone models were obtained with implant analogs. Abutment heights of 1–2 and 2.5–4 mm were used on the vestibular and lingual sides, respectively. Crowns were cemented and cleaned, and half of the samples were cleaned again using PEEK tips. The abutment-crown suprastructure was then disconnected, and cleaning efficacy was evaluated. Varying amounts of excess cement were found on all specimens except for the PEEK group with abutment-crown connections 1 mm below the gingival margin. An increase of undetected cement remnants was observed when the restoration margins were located deeper subgingivally. Various amounts of excess cement associated with margin location were detected on the abutment–restoration complex despite meticulous cleaning efforts. Ultrasonic PEEK tips were effective at cleaning the cement remnants around implants to a certain depth.

Publisher

American Academy of Implant Dentistry

Subject

Oral Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3