Detection of Residual Excess Zinc Oxide–Based Cement With Laser Fluorescence (DIAGNOdent): In Vitro Evaluation

Author:

Alikhasi Marzieh1,Zadeh Behnoush Yaghoub2,Mansourian Arash3,Nokhbatolfoghahaei Hanieh4

Affiliation:

1. Dental Research Center, Laser Research Center, Dentistry Research Institute, School of Dentistry, Department of Prosthodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran.

2. Laser Research Center of Dentistry, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran.

3. Department of Oral Medicine, Faculty of Dentistry, Tehran University of Medical Sciences, Tehran, Iran.

4. Dental Research Center, Research Institute of Dental Sciences, Shahid Beheshti University of Medical Sciences, Tehran, Iran.

Abstract

Because of its importance in the development of peri-implant mucositis and peri-implantitis, detection of residual excess cement (REC) is often the focus of studies addressing cement-retained implant-supported restorations. The purpose of this study was to evaluate the sensitivity and specificity of laser fluorescence (DIAGNOdent) for detecting residual excess zinc oxidebased cement around dental implants. In this in vitro study, 15 tissue-level implants were embedded in acrylic resin. To simulate gingiva around the implants, the transgingival part of each implant was covered with a gingival mask silicon material. Cement (Tempobond; 1 × 1 × 1 mm) was applied to 30 areas, 4 mm below the gingival-mimicking line using a custom-made template. A DIAGNOdent laser device was used by 2 independent examiners to evaluate the presence or absence of cement in a selected area. The examiners were allowed to probe the gingival sulcus (2-mm depth) 2 times with a 5-minute interval between tests. The residual cement was recognized by gently walking the device tip around the implant. A detection score less than 16 indicated an absence of cement, and scores of 16 or greater indicated the presence of excess luting agent in the implant sulcus. The sensitivity and specificity of DIAGNOdent to detect REC in the sulcus were 100% and 96.67%, respectively. Based on our findings, we propose that DIAGNOdent could be used to detect REC in the sulcus of cement-retained implant supported restorations.

Publisher

American Academy of Implant Dentistry

Subject

Oral Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3