Prosthetically CAD-CAM–Guided Bone Augmentation of Atrophic Jaws Using Customized Titanium Mesh: Preliminary Results of an Open Prospective Study

Author:

Ciocca Leonardo1,Lizio Giuseppe2,Baldissara Paolo1,Sambuco Alessandro3,Scotti Roberto1,Corinaldesi Giuseppe2

Affiliation:

1. Section of Prosthodontics, Department of Biomedical and Neuromotor Science, Alma Mater Studiorum, University of Bologna, Bologna, Italy.

2. Section of Oral Surgery, Department of Biomedical and Neuromotor Science, Alma Mater Studiorum, University of Bologna, Bologna, Italy.

3. Private practice, Bologna, Italy.

Abstract

This study evaluated the outcomes of computer-aided design–computer-aided machining (CAD-CAM)–customized titanium mesh used for prosthetically guided bone augmentation related to the occlusion-driven implant position, to the vertical bone volume gain of the mandible and maxilla, and to complications, such as mesh exposure. Nine patients scheduled for bone augmentation of atrophic sites were treated with custom titanium mesh and particulate bone grafts with autologous bone and anorganic bovine bone in a 1:1 ratio prior to implant surgery. The bone volume needed to augment was virtually projected based on implant position, width, and length, and the mesh design was programmed for the necessary retaining screws. After 6 to 8 months, bone augmentations of 1.72 to 4.1 mm (mean: 3.83 mm) for the mandibular arch and 2.14 to 6.88 mm (mean: 3.95 mm) for the maxilla were registered on cone-beam computerized tomography. Mesh premature (within 4 to 6 weeks) exposure was observed in 3 cases and delayed (after 4 to 6 weeks) in 3 other cases. One titanium mesh was removed before the programmed time but in all augmented sites was possible implant insertion. No complication occurred during prosthetic follow-up. Using CAD-CAM technology for prosthetically guided bone augmentation showed important postoperative morbidity of mesh exposure (66%). Because of this high prevalence of mesh exposure and the potential infection that could affect the expected bone augmentation, this study suggests a cautious approach to this procedure when designing the titanium mesh, to avoid flap tension that may cause mucosal rupture.

Publisher

American Academy of Implant Dentistry

Subject

Oral Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3