1. Department of Maxillofacial Prosthodontics, Faculty of Dentistry, Istanbul University, Turkey.
Abstract
The aim of this study was to evaluate the effects of bruxing forces on implants configured under 2 different occlusal schemes by dynamic finite element analysis. A main model consisting of a 5-unit fixed partial denture supported by 3 implants was simulated with bone, implants, and superstructures. All calculations were made individually for each component, namely porcelain crowns, abutments, abutment screws, implants, and bone. Maximum stresses were found in the group-function occlusion. Group-function loading may result excess stresses on the components compared with canine-guidance loading. According to the results of this study, use of canine guidance is encouraged in bruxers with implant-supported prostheses.