Comparative Evaluation of a Lower-Dose CBCT Acquisition Protocol for Preoperative Implant Site Assessment in Dry Human Skulls: A Proof-of-Concept Study

Author:

Tadinada Aditya1,Proft Bailey2,Thacker Sejal3,Yadav Sumit4

Affiliation:

1. 1 University of Connecticut School of Dental Medicine, Farmington, CT, USA.

2. 2 Private practice, Katy, TX, USA.

3. 3 University of Connecticut School of Dental Medicine, Farmington, CT, USA.

4. 4 University of Connecticut School of Dental Medicine, Farmington, CT, USA.

Abstract

Restoration of edentulous sites with dental implants is increasingly becoming a popular choice. Cross-sectional 3-dimensional imaging using cone-beam computed tomography (CBCT) provides a better depiction of the implant site to help the clinician plan the procedure better. In spite of the advantages, radiation dose will always remain a concern. The evolution of lower-dose protocols is ongoing, but whether those acquisition protocols yield comparable diagnostic information is still not well established. The objective of this study was to evaluate the diagnostic efficacy of a low-dose, 180° rotational CBCT acquisition protocol for evaluating a potential implant site in comparison with a conventional 360° rotational acquisition. Ten dentate and partially edentulous dry human skulls providing 82 randomized implant sites—40 in the maxilla and 42 in the mandible—were chosen for this study. Each skull was imaged using a 360° and a 180° rotational acquisition on a J. Morita Accuitomo CBCT scanner. Evaluation of cortical and trabecular bone, height, width, and proximity to critical structures, such as the inferior alveolar nerve canal and the maxillary sinus, were measured. An oral surgeon and an oral radiologist rated the diagnostic efficacy of the scans by evaluating the above characteristics. Statistical evaluation of the data with linear regression showed significant agreement between both protocol measurements. Kappa analyses yielded a good interobserver agreement. In this proof-of-concept study, CBCT imaging using the lower-dose, modified arc, and 180° acquisition protocol shows comparable results to the conventional 360° protocol for preoperative implant assessment.

Publisher

American Academy of Implant Dentistry

Subject

Oral Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3