Affiliation:
1. Scientific Centre for Expert Evaluation of Medicinal Products
2. Federal Medical Biological Agency
Abstract
Scientific relevance. The immunoglobulin A (IgA) impurity content in parenteral human immunoglobulins should be determined in accordance with the State Pharmacopoeia of the Russian Federation by kinetic nephelometry, radial immunodiffusion, or enzyme immunoassay (ELISA) with a reference standard. The International Standard (IS) for the content of IgA is certified using gravimetry and radial immunodiffusion. However, neither of the existing standards for the content of IgA in human immunoglobulins is currently certified using all three compendial methods. This prevents analysts from comparing test results obtained by different methods and may lead to an underestimation of the IgA content in human immunoglobulins.Aim. This study aimed to determine the procedure for the development, certification, and use of a pharmacopoeial reference standard (RS) for the content of IgA in human immunoglobulins.Materials and methods. The authors studied candidate RSs for the IgA content derived from human plasma for fractionation. The IgA content determination involved kinetic nephelometry, radial immunodiffusion, and ELISA, as well as commercial test kits and the IS. The authors quantified the IgA impurity in samples of commercial human immunoglobulins from various manufacturers. The data analysis involved descriptive statistics and variance analysis using Microsoft Excel and Statistica 10.Results. The authors established a pharmacopoeial standard with a certified IgA content of 1.98 mg/mL (expanded uncertainty, 0.44 mg/mL; coverage coefficient, k=2; confidence level, 95%) for IgA impurity quantification in human immunoglobulins by radial immunodiffusion and ELISA and that of 1.31–2.64 mg/mL (expanded uncertainty, 0.67 mg/mL; coverage ratio, k=3; confidence level, 99%) for intralaboratory quality control of IgA impurity quantification by kinetic nephelometry, radial immunodiffusion, and ELISA.Conclusions. The pharmacopoeial standard developed in the study has been included in the register of standards of the State Pharmacopoeia of the Russian Federation as the Reference Standard for the Content of Immunoglobulin Class A (IgA) (Registry No. 3.1.00454). The pharmacopoeial standard is intended for the standardisation of analytical methods for the-determination of the IgA impurity content in parenteral human immunoglobulins.
Subject
General Earth and Planetary Sciences,General Environmental Science
Reference4 articles.
1. Esmaeilzadeh H, Askarisarvestani A, Hosseini N, Samimi S, Shafiei A, Mahdaviani SA, et al. Adverse reactions in a large cohort of patients with inborn errors of immunity receiving intravenous immunoglobulin. Clin Immunol. 2021;230:108826. https://doi.org/10.1016/j.clim.2021.108826
2. Kornilova OG, Krivykh MA, Volkova RA, Borisevich IB. Reference materials used for specific safety evaluation of human immunoglobulin and human albumin products: features of development, certification and application. Measurement Standards. Reference Materials. 2018;(3–4):33–41 (In Russ.). https://doi.org/10.20915/2077-1177-2018-14-3-4-33-41
3. Glantz S. Primer of biostatistics. Moscow: Practice; 1998 (In Russ.).
4. Kudasheva EYu, Nechaev AV, Leshina SA, Volkova RA, Klepikova AG. Composition for determining the content of IgA immunoglobulins in medicinal products. Patent of the Russian Federation No. 2794887; 2023 (In Russ.). EDN: RUUTJV
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献