Reliability of the Pediatric Specific Musculoskeletal Ultrasound Scoring Systems for the Elbow, Wrist, and Finger Joints

Author:

Vega-Fernandez PatriciaORCID,Esteban Ysabella,Oberle Edward,Proulx-Gauthier Jean-Philippe,Clark Matthew,Shenoi SusanORCID,Thatayatikom Akaluck,Benham Heather,Brunner Emily J.,Woolnough Leandra,Henrickson Michael,Pratt Laura R.,De Ranieri DeirdreORCID,Hoffmann Sarah,Janow Ginger,Bukulmez Hulya,Altaye Mekibib,Cassedy Amy,Ting Tracy V.,Roth Johannes

Abstract

ObjectiveMusculoskeletal ultrasound (MSUS) is increasingly being used in the evaluation of pediatric musculoskeletal diseases. In order to provide objective assessments of arthritis, reliable MSUS scoring systems are needed. Recently, joint-specific scoring systems for arthritis of the pediatric elbow, wrist, and finger joints were proposed by the Childhood Arthritis and Rheumatology Research Alliance (CARRA) MSUS workgroup. This study aimed to assess the reliability of these scoring systems when used by sonographers with different levels of expertise.MethodsMembers of the CARRA MSUS workgroup attended training sessions for scoring the elbow, wrist, and finger. Subsequently, scoring exercises of B mode and power Doppler (PD) mode still images for each joint were performed. Interreader reliability was determined using 2-way single-score intraclass correlation coefficients (ICCs) for synovitis and Cohenfor tenosynovitis.ResultsSeventeen pediatric rheumatologists with different levels of MSUS expertise (1-15 yrs) completed a 2-hour training session and calibration exercise for each joint. Excellent reliability (ICC > 0.75) was found after the first scoring exercise for all the finger and elbow views evaluated on B mode and PD mode, and for all of the wrist views on B mode. After a second training session and a scoring exercise, the wrist PD mode views reached excellent reliability as well.ConclusionThe preliminary CARRA MSUS scoring systems for assessing arthritis of the pediatric elbow, wrist, and finger joints demonstrate excellent reliability among pediatric MSUS sonographers with different levels of expertise. With further validation, this reliable joint-specific scoring system could serve as a clinical tool and scientific outcome measure.

Publisher

The Journal of Rheumatology

Subject

Immunology,Immunology and Allergy,Rheumatology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3