Development and Testing of Reduced Versions of the Manual Muscle Test-8 in Juvenile Dermatomyositis

Author:

Rosina SilviaORCID,Varnier Giulia C.ORCID,Pistorio AngelaORCID,Pilkington ClarissaORCID,Maillard Susan,Civino AdeleORCID,Tsitsami ElenaORCID,Bracaglia ClaudiaORCID,Jelusic MarijaORCID,Cespedes-Cruz Adriana,Espada Graciela,Cimaz RolandoORCID,Couillault GerardORCID,Joos RikORCID,Quartier PierreORCID,Rao Anand P.,Malattia ClaraORCID,Ruperto NicolinoORCID,Consolaro AlessandroORCID,Ravelli AngeloORCID

Abstract

Objective.To develop and test shortened versions of the Manual Muscle Test-8 (MMT-8) in juvenile dermatomyositis (JDM).Methods.Construction of reduced tools was based on a retrospective analysis of individual scores of MMT-8 muscle groups in 3 multinational datasets. The 4 and 6 most frequently impaired muscle groups were included in MMT-4 and MMT-6, respectively. Metrologic properties of reduced tools were assessed by evaluating construct validity, internal consistency, discriminant ability, and responsiveness to change.Results.Neck flexors, hip extensors, hip abductors, and shoulder abductors were included in MMT-4, whereas MMT-6 also included elbow flexors and hip flexors. Both shortened tools revealed strong correlations with MMT-8 and other muscle strength measures. Correlations with other JDM outcome measures were in line with predictions. Internal consistency was good (0.88–0.96) for both MMT-4 and MMT-6. Both reduced tools showed strong ability to discriminate between disease activity states, assessed by the caring physician or a parent (P < 0.001), and between patients whose parents were satisfied or not satisfied with illness course (P < 0.001). Responsiveness to change (assessed by both standardized response mean and relative efficiency) of MMT-4 and, to a lesser degree, MMT-6, was slightly superior to that of MMT-8.Conclusion.Overall, the metrologic performance of MMT-4 and MMT-6 was comparable to that of the other established muscle strength tools, which indicates that they may be suitable for use in clinical practice and research, including clinical trials. The measurement properties of these tools should be further tested in other patient populations and evaluated prospectively.

Publisher

The Journal of Rheumatology

Subject

Immunology,Immunology and Allergy,Rheumatology

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3