Measurement of lung tissue mass, thoracic blood and interstitial volumes by transmission/emission scanning using [99mTc]pertechnetate

Author:

Briggs B. A.1,Bradley T. M.1,Vernon P.2,Cooke N. T.1,Drinkwater C.2,Gillett M. K.1,Snashall P. D.1

Affiliation:

1. Department of Medicine, Charing Cross and Westminster Medical School, Charing Cross Hospital, London

2. Department of Nuclear Medicine, Charing Cross Hospital, London

Abstract

1. We have developed a method for non-invasive measurement of lung tissue mass, thoracic blood and interstitial volumes by a combination of transmission and emission scanning with technetium isotope (99mTc). 2. In a lung model we demonstrated that emission counts could be successfully corrected for attenuation with data obtained by transmission scanning, despite an uneven distribution of radioactivity and attenuation in the model. 3. In dogs we compared regional transthoracic tissue thickness, measured by transmission scanning, and regional ‘thickness’ of blood measured by transmission/emission scanning with direct gravimetric measurements made post mortem. Scanning and direct measurements correlated significantly. 4. In man we used a [99mTc]pertechnetate (99mTcO4) flood source to obtain antero–posterior transmission scans with a gamma-camera. The thickness of attenuating tissue was estimated in each pixel. Scans were obtained of thoracic blood (by labelling erythrocytes with 99mTcO4) and of interstitium (with 99mTc-labelled diethylene-triaminepenta-acetic acid and subtraction of the blood image). We used a computer program to correct the emission scans for attenuation using the transmission scan derived tissue thickness, pixel by pixel. Finally we took a lateral chest radiograph to estimate chest wall thickness. 5. In normal man lung tissue thickness at hilar level was 3.1 ± 0.5 cm (n = 8). Thoracic blood thickness increased from the apex downwards in the upright lung, being 1.2 ± 0.1 cm at the hilar level and 2.0 ± 0.3 cm at the lung base. Interstitial thickness was 0.8 ± 0.3 cm at the hilum and 0.85 ± 0.2 at the base. These values compare well with data in the literature. 6. In emphysema (n = 5) lung tissue and blood thickness were decreased; interstitial thickness was normal. In patients with interstitial pneumonitis (n = 7) lung tissue thickness was approximately doubled, and interstitial thickness similarly increased. In two patients with acute pulmonary sarcoidosis interstitial thickness was not increased despite a marked increase in lung tissue thickness. 7. In conclusion, this technique gives information not readily obtainable by other methods, which may be of clinical utility. Further evaluation and development is warranted.

Publisher

Portland Press Ltd.

Subject

General Medicine

Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3