Heart rate increment: an electrocardiological approach for the early detection of obstructive sleep apnoea/hypopnoea syndrome

Author:

ROCHE Frédéric1,SFORZA Emilia2,DUVERNEY David1,BORDERIES Jean-René3,PICHOT Vincent1,BIGAIGNON Odile3,ASCHER Gilles3,BARTHÉLÉMY Jean-Claude1

Affiliation:

1. Service d'Exploration Fonctionnelle CardioRespiratoire, Laboratoire de Physiologie-PPEH, Groupe de Recherche SYNAPSE, CHU Nord, Faculté de Médecine Jacques Lisfranc, Université Jean Monnet, Saint-Etienne, France

2. Laboratoire du Sommeil, Laboratoire de NeuroPhysiologie, Hôpital Belle Idée, Hôpitaux Universitaires, Geneva, Switzerland

3. Novacor SA, Rueil-Malmaison, France

Abstract

The prevalence of OSAHS (obstructive sleep apnoea/hypopnoea syndrome) is high in developed countries and it is estimated that the vast majority of patients remain undiagnosed. On the basis of physiological evidence, we evaluated the frequency component of HRI (heart rate increment) as a simple and inexpensive screening tool for OSAHS detection in a first group of patients (group 1) and validated their discriminant capacity in a second group (group 2). The predictive accuracy of hourly %VLFI (frequency-domain HRI variable obtained from nocturnal ECG Holter monitoring) was analysed by comparison with an hour-by-hour respiratory disturbances index assessed by complete polysomnography in 28 consecutive clinically suspected OSAHS patients for group 1 and in 35 patients for group 2. OSAHS was present in 20 patients according to a mean hourly apnoea plus hypopnoea index >10 in group 1, and prevalence reached 77.1% in group 2. Sensitivity, specificity and positive and negative predictive accuracy were calculated and an ROC (receiver operating characteristic) curve was constructed for several polysomnographic threshold values. In group 1, hourly %VLFI appeared as an evident predictor of the apnoea/hypopnoea index (W=0.848, P<0.0001; where W is the area under the curve obtained using ROC curve analysis). Using an appropriate threshold (value ≥3.2%), %VLFI demonstrated a sensitivity of 78.1% and a specificity of 70.4%. These thresholds applied to group 2 yielded a sensitivity of 73.9% and a specificity of 76.6%. Frequency-domain analysis of the HRI appears to be a powerful tool for OSAHS prediction. The simplicity of its analysis and use makes of it a particularly well-suited variable for routine mass screening in high-risk populations undergoing ECG Holter monitoring.

Publisher

Portland Press Ltd.

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3