Abstract
This paper describes a manual method for N-terminal sequence analysis of polypeptides at subnanomole sensitivity. The polypeptide is degraded stepwise by using the dimethylaminoazobenzene isothiocyanate/phenyl isothiocyanate double-coupling method, and the released dimethylaminoazobenzenethiohydantoins of amino acids were identified by reversed-phase high-pressure liquid chromatography. The dimethylaminoazobenzenethiohydantoins are coloured compounds and can be detected in the visible region with the sensitivity limit of 1 pmol (signal-to-baseline noise ratio 5). A high-pressure liquid-chromatographic method was developed for complete analysis of all amino acid dimethylaminoazobenzenethiohydantoin derivatives, including the by-products of serine and threonine. Thus, without use of an automatic sequenator or radioactive materials, it is possible to determine the complete sequence of peptides and N-terminal sequence of proteins with less than 1 nmol of material.
Subject
Cell Biology,Molecular Biology,Biochemistry
Cited by
81 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献