Author:
Gifuni A.,Sorrentino A.,Fanti A.,Ferrara G.,Migliaccio M.,Mazzarella G.,Corona F.
Abstract
The shielding effectiveness (SE) has become afundamental step in testing active or passive electricdevices. The Reverberating Chamber (RC) is a wellestablishedmethod for determining the SE since has theadvantage to expose the material to a more realisticenvironment. In this paper the SEe of electrically largeenclosure with a metallic mesh grid in a RC is evaluated.Enclosures made with metallic mesh are considered. Inparticular, it is shown that the SE of a material is unable toprovide complete information for the SEe of electricallylarge enclosure made with the same material. Moreover,this latter one is related to the loading conditions within theenclosure itself. Measurements accomplished at RC of theUniversità di Napoli Parthenope (formerly IstitutoUniversitario Navale, IUN) confirm the physical soundnessof the proposed approach.
Publisher
Advanced Electromagnetics
Subject
Electrical and Electronic Engineering,Radiation,Electronic, Optical and Magnetic Materials
Cited by
17 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献