Abstract

The objective: to compare efficacy and safety of Intellivent-ASV® with conventional ventilation modes during weaning in the patients after cardiac surgery.Subjects and methods. In this randomized controlled trial, 40 adult patients were ventilated with conventional ventilation modes and 40 with Intellivent-ASV after uncomplicated cardiac surgery. Eight physicians were involved in the study.Care of both groups was standardized, except for the modes of postoperative ventilation.We compared:- The physician’s workload, through accounting number of manual ventilator settings and time they spent near the ventilator in every group,- Duration of tracheal intubation in ICU,- Evaluation of ventilation safety by considering driving pressure, mechanical power, positive end expiratory pressure, and tidal volume level,- The frequency of adverse events, postoperative complications, and lethality.Results. There were significant differences in the duration of respiratory support in ICU: 226 ± 31 min (Intellivent Group) vs 271 ± 78 min (Control Group) (p = 0.0013).In Intellivent Group, the number of manual ventilator settings and time spent by physicians near the ventilator before tracheal extubation were significantly lower: 0 vs 4 (2–6), and 35 (25–53) sec vs 164 ± 69 sec respectively (p < 0.001 in both cases).Intellivent-ASV provided significantly more protective ventilation through reduction in the driving pressure, tidal volume, FiO2 and PEEP levels but no difference was noted between paO2/FiO2 ratio. ∆P and Vt were significantly lower in Intellivent Group – ∆P on mechanical ventilation was 6 (5–7) cm H2O vs 7.25 (6.5–9.5) cm H2O (p < 0.001); Vt on mechanical ventilation was 6 (5.2–7) vs 7 (6–9.5) ml/kg/PBW (p = 0.000003). PEEP and FiO2 levels were also significantly lower in Intellivent Group, PEEP on mechanical ventilation was 5 (5–7.5) cm H2O vs 7 (5–11.5) cm H2O and FiO2 level was 26 (22–30) % vs 34 (30–40) %.There were no significant differences between the groups in frequency of adverse events and duration of ICU and hospital stay.Conclusion. Application of Intellivent-ASV mode after uncomplicated cardiac surgery provides more protective mechanical ventilation and reduces the physician’s workload without compromising the quality of respiratory support and safety of patients.

Publisher

New Terra

Subject

General Materials Science

Reference22 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3