Safety and Success Rates of Excimer Laser Sheath–Assisted Retrieval of Embedded Inferior Vena Cava Filters

Author:

Desai Kush R.1,Kaufman John2,Truong Parker3,Lindquist Jonathan D.4,Ahmed Osman5,Flanagan Siobhan M.6,Garcia Mark J.78,Ram Rashmi9,Gao Yu-Rong9,Lewandowski Robert J.1,Ryu Robert K.10

Affiliation:

1. Department of Radiology, Northwestern University, Chicago, Illinois

2. Department of Interventional Radiology, Oregon Health & Science University, Portland

3. Department of Interventional Radiology, Oklahoma Heart Hospital, Oklahoma City

4. Division of Vascular and Interventional Radiology, Department of Radiology, University of Colorado Anschutz Medical Center, Aurora

5. Department of Radiology, The University of Chicago, Chicago, Illinois

6. Division of Vascular and Interventional Radiology, Department of Radiology, University of Minnesota Medical Center, Minneapolis

7. EndoVascular Consultants, Wilmington, Delaware

8. Department of Radiology, Trinity Health, Saint Francis Healthcare, Wilmington, Delaware

9. Department of Clinical & Medical Affairs, Philips North America LLC, Cambridge, Massachusetts

10. Department of Radiology, Keck School of Medicine, University of Southern California, Los Angeles

Abstract

ImportanceDespite historically high rates of use, most inferior vena cava (IVC) filters are not retrieved. The US Food and Drug Administration safety communications recommended retrieval when the IVC filter is no longer indicated out of concern for filter-related complications. However, failure rates are high when using standard techniques for retrieval of long-dwelling filters, and until recently, there have been no devices approved for retrieval of embedded IVC filters.ObjectiveTo evaluate the safety and success of excimer laser sheath–assisted retrieval of embedded IVC filters.Design, Setting, and ParticipantsA retrospective, multicenter, clinical cohort study of excimer laser sheath–assisted IVC filter retrievals from 7 US sites was conducted between March 1, 2012, and February 28, 2021, among 265 patients who underwent IVC filter retrieval using the laser. Patients were substratified between a high-volume single center and a multicenter data set. A blinded physician committee adjudicated reported complications and their association with use of the laser.ExposuresRetrieval of IVC filters using excimer laser sheath.Main Outcomes and MeasuresThe primary safety end point was device-related major complication rate (Society of Interventional Radiology categories C to F, which included any adverse event associated with morbidity or disability that increases the level of care, results in hospital admission, or substantially lengthens the hospital stay). The primary success end point was technical success of IVC filter retrieval. The primary end points were compared with literature-derived, meta-analysis–suggested target performance goals.ResultsThe single-center experience included 139 participants (mean [SD] age, 52 [16] years; 78 female participants [56.1%]), and the multicenter experience included 126 participants (mean [SD] age, 52 [16] years; 75 female participants [59.5%]). The device-related major complication rate was 2.9% (4 of 139; 95% CI, 0.8%-7.2%; P = .001) for the single-center experience and 4.0% (5 of 126; 95% CI, 1.3%-9.0%; P = .01) for the multicenter experience, both of which were significantly lower than the primary safety performance goal (10%). No major complications were considered to be definitively associated with use of the laser. The technical success rate was 95.7% (133 of 139; 95% CI, 90.8%-98.4%; P = .007) for the single-center experience and 95.2% (120 of 126; 95% CI, 89.9%-98.2%; P = .02) for the multicenter experience, both of which were significantly higher than the primary performance goal (89.4%).Conclusions and RelevanceThis cohort study demonstrated high technical success and low complication rates of excimer laser sheath–assisted retrieval of embedded IVC filters in centers with variable case volume and experience, which suggests a wide applicability of the technique with proper training. The excimer laser sheath offers physicians a valuable tool for retrieval of challenging embedded IVC filters.

Publisher

American Medical Association (AMA)

Subject

General Medicine