Long-term Outcomes of Transcatheter Aortic Valve Replacement With the Lotus Valve vs CoreValve/EvolutR

Author:

Rizik David G.1,Rajagopal Vivek2,Makkar Raj R.3,Bajwa Tanvir4,Kleiman Neal S.5,Linke Axel6,Kereiakes Dean J.7,Waksman Ron8,Thourani Vinod H.9,Stoler Robert C.10,Mishkel Gregory J.11,Iyer Vijay S.12,Buchbinder Maurice13,Götberg Matthias14,Bjursten Henrik15,Allocco Dominic J.16,Reardon Michael J.17

Affiliation:

1. Department of Cardiology, HonorHealth and the Scottsdale-Lincoln Health Network, Scottsdale, Arizona

2. Cardiology Department, Piedmont Hospital, Atlanta, Georgia

3. Smidt Heart Institute, Cedars-Sinai Medical Center, Los Angeles, California

4. Department of Medicine, Aurora St Luke's Medical Center, Milwaukee, Wisconsin

5. Department of Cardiology, Houston Methodist DeBakey Heart and Vascular Center, Houston, Texas

6. Department of Internal Medicine and Cardiology, Technische Universität Dresden, Dresden, Germany

7. The Christ Hospital Heart and Vascular Center/The Lindner Research Center Cincinnati, Cincinnati, Ohio

8. Section of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC

9. Department of Cardiovascular Surgery, Marcus Valve Center, Piedmont Heart Institute, Atlanta, Georgia

10. Baylor Heart & Vascular Hospital, Dallas, Texas

11. Division of Cardiology, NorthShore University HealthSystem, University of Chicago Pritzker School of Medicine, Chicago, Illinois

12. Gates Vascular Institute, Interventional Cardiology, University at Buffalo, School of Medicine and Biomedical Sciences, Buffalo, New York

13. Department of Cardiology, Foundation for Cardiovascular Medicine, Stanford University, Stanford, California

14. Department of Cardiology, Clinical Sciences, Lund University, Skane University Hospital, Lund, Sweden

15. Department of Cardiothoracic Surgery, Skåne University Hospital, Lund, Sweden

16. Boston Scientific Corp, Marlborough, Massachusetts

17. Department of Cardiovascular Surgery, Houston Methodist DeBakey Heart and Vascular Center, Houston, Texas

Abstract

ImportanceLong-term follow-up after transcatheter aortic valve replacement (TAVR) is of interest given that longitudinal data on mortality and durability of transcatheter heart valves are limited. The REPRISE III (Repositionable Percutaneous Replacement of Stenotic Aortic Valve Through Implantation of Lotus Valve System—Randomized Clinical Evaluation) randomized clinical trial compared the mechanically expanded Lotus valve with the self-expanding CoreValve/EvolutR TAVR platforms.ObjectiveTo describe the final 5-year outcomes of the REPRISE III trial.Design, Setting, and ParticipantsThis prespecified secondary analysis assessed the final 5-year clinical, functional, and echocardiographic outcomes of 912 patients from the REPRISE III trial, which was conducted at 55 centers in North America, Europe, and Australia between September 22, 2014, and December 24, 2015. Patients had high risk for aortic stenosis or severe or symptomatic aortic stenosis. Data were analyzed from September 22, 2014, to May 21, 2021.InterventionLotus valve or CoreValve/EvolutR TAVR platforms.Main Outcomes and MeasuresValve Academic Research Consortium-2 end points, hemodynamic measures, functional status, and health status were examined through the 5-year follow-up.ResultsA total of 912 patients (mean [SD] age, 82.8 [7.3] years; 463 women [50.8%]) were randomized to either the Lotus valve group (n = 607) or CoreValve/EvolutR group (n = 305), with a baseline Society of Thoracic Surgeons risk score of 6.8%. Clinical follow-up data from the REPRISE III trial were available for 581 patients (95.7%) in the Lotus valve group and 285 patients (93.4%) in the CoreValve/EvolutR group. At 5 years, the cumulative event rate for all-cause mortality was 50.9% in the Lotus valve group vs 52.8% in the CoreValve/EvolutR group (P = .59). Disabling stroke was less frequent with the Lotus valve vs CoreValve/EvolutR (cumulative event rates, 8.3% vs 12.2%; P = .04), whereas the cumulative event rates for overall stroke were similar in both groups (14.1% vs 15.3%; P = .38). Insertion of a new permanent pacemaker (38.9% vs 27.3%; P < .001) and detection of prosthetic aortic valve thrombosis (5.8% vs 1.8%; P = .007) were more common in the Lotus valve group than in the CoreValve/EvolutR group. A smaller proportion of patients who received the Lotus valve experienced valve malpositioning (0% vs 2.6%; P < .001) and required the use of a second valve (1.0% vs 3.8%; P < .001) during the procedure compared with those who received the CoreValve/EvolutR. Compared with the Lotus valve group, the CoreValve/EvolutR group had a significantly lower mean (SD) aortic gradient (7.8 [4.2] mm Hg vs 12.6 [6.7] mm Hg; P < .001) and larger valve areas (1.57 [0.56] cm2 vs 1.42 [0.42] cm2; P = .10). After 5 years, the proportion of patients with moderate or greater paravalvular leak was not significantly higher with the CoreValve/EvolutR than with the Lotus valve (1.9% vs 0%; P = .31); however, the proportion of patients with mild paravalvular leak was higher in the CoreValve/EvolutR group compared with the Lotus valve group (23.1% vs 7.8%; P = .006). Long-term, similar improvements in New York Heart Association class and Kansas City Cardiomyopathy Questionnaire score were observed in both groups.Conclusions and RelevanceThe REPRISE III trial found that, at 5 years, the clinical outcomes of the Lotus valve were comparable to those of the CoreValve/EvolutR and that the Lotus valve was safe and effective.Trial RegistrationClinicalTrials.gov Identifier: NCT02202434