Author:
Korkmaz Yasemin Nur,Arslan Semiha
Abstract
ABSTRACT
Objectives
To compare the transfer accuracy of four different lingual retainer (LR) transfer methods using three-dimensional digital models.
Materials and Methods
Four groups of 17 patients each were created: finger transfer (FT), silicone key transfer (SKT), acrylic resin transfer (ART), and indirect bonding (IDB). At the end of orthodontic treatment, the mandibular dental casts of patients were scanned with the LR wire. Then, intraoral scanning of the mandibular arches was performed after bonding the retainer wires. Linear and angular measurements were made using software on superimposed digital models.
Results
Horizontal and vertical errors among the teeth were not significantly different among the FT, SKT, and ART groups. However, in the IDB group, linear transfer errors showed significant differences among the different teeth. The tip and rotation errors in the FT group were not significantly different among the teeth. The angular errors were lower in canines than in the incisors. In all measured parameters, the SKT group showed the lowest errors, whereas the FT group had the highest transfer errors in all parameters except vertical.
Conclusions
Among the transfer methods tested, SKT was determined to have the highest clinical accuracy.
Publisher
The Angle Orthodontist (EH Angle Education & Research Foundation)
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献