Does anchorage loss differ with 0.018-inch and 0.022-inch slot bracket systems?

Author:

Yassir Yassir A.1,McIntyre Grant T.2,El-Angbawi Ahmed M.3,Bearn David R.4

Affiliation:

1. Assistant Professor, Orthodontic Department, College of Dentistry, University of Baghdad, Baghdad, Iraq; and School of Dentistry, University of Dundee, Dundee, United Kingdom.

2. Honorary Professor, Orthodontics. School of Dentistry, University of Dundee, Dundee, United Kingdom.

3. Honorary Lecturer, Orthodontics. School of Dentistry, University of Dundee, Dundee, United Kingdom.

4. Professor, Orthodontics. School of Dentistry, University of Dundee, Dundee, United Kingdom.

Abstract

ABSTRACT Objectives: To compare maxillary first molar anchorage loss between 0.018-inch and 0.022-inch slot fixed appliance systems. Materials and Methods: Patients requiring bilateral maxillary premolar extractions (n = 74) within a randomized clinical trial comparing the effectiveness of 0.018-inch and 0.022-inch slot MBT bracket systems (3M-Unitek, Monrovia, Calif) were included. Three-dimensional pre- and posttreatment digital models were landmarked and measured (R700 scanner and OrthoAnalyzer software, 3Shape, Copenhagen, Denmark). Anteroposterior position of the first molars was measured using the third medial rugae point as a reference. Anchorage loss (AL) represented the subtraction of the posttreatment distance from the pretreatment distance for both anchorage loss right (ALR) and left (ALL) sides. The values were then compared using a two-way analysis of variance. Results: There were 41 and 33 cases for the 0.018-inch and 0.022-inch bracket slot systems, respectively. The baseline characteristics were similar between groups, except for the presence or absence of anchorage devices (P = .050). For the total sample: 0.018-inch ALR = 3.86 mm, ALL = 3.30 mm and 0.022-inch ALR = 3.73 mm, ALL = 3.47 mm (P = .970). There was also no significant difference between the 0.018-inch and 0.022-inch groups when subjects with anchorage devices were excluded (P = .383). Conclusions: Bracket slot size does not influence maxillary molar anchorage loss during orthodontic treatment.

Publisher

The Angle Orthodontist (EH Angle Education & Research Foundation)

Subject

Orthodontics

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3