Evaluation of miniscrew stability using an automatic embedding auxiliary skeletal anchorage device

Author:

Oga Yasuhiko1,Tomonari Hiroshi2,Kwon Sangho2,Kuninori Takaharu2,Yagi Takakazu2,Miyawaki Shouichi3

Affiliation:

1. Postgraduate student, Field of Developmental Medicine, Health Research Course, Department of Orthodontics and Dentofacial Orthopedics, Graduate School of Medical and Dental Sciences, Kagoshima University, Kagoshima, Japan.

2. Assistant Professor, Field of Developmental Medicine, Health Research Course, Department of Orthodontics and Dentofacial Orthopedics, Graduate School of Medical and Dental Sciences, Kagoshima University, Kagoshima, Japan.

3. Professor and Department Chair, Field of Developmental Medicine, Health Research Course, Department of Orthodontics and Dentofacial Orthopedics, Graduate School of Medical and Dental Sciences, Kagoshima University, Kagoshima, Japan.

Abstract

ABSTRACT Objective: To clarify the in vivo effect of an automatic embedding device on miniscrew stability. Materials and Methods: 42 miniscrews were implanted into rabbit femurs. The miniscrews with the novel auxiliary device formed the auxiliary group (n = 11 at 4 weeks; n = 11 at 8 weeks) and the miniscrews without the auxiliary device formed the nonauxiliary control group (n = 9 at 4 weeks; n = 11 at 8 weeks). Cortical bone thickness, distance from the cortical bone surface to the miniscrew head, and implantation depth of the spike were measured using micro-computed tomography. The mechanical retention force was evaluated by measuring the displacement of the miniscrew head after it was loaded perpendicular to its long axis. In the lateral displacement test, effects of the auxiliary (with vs without auxiliary), and time (4 vs 8 weeks) were assessed using the Brunner–Langer nonparametric analysis of longitudinal data in factorial experiments. Results: The mean implantation depth of the spike in the auxiliary group at 4 and 8 weeks was 0.28 mm (median: 0.33; SD: 0.12) and 0.37 mm (median: 0.33; SD: 0.19), respectively. The retention force was approximately 2.0 to 2.8 and 1.6 to 1.8 times greater in the auxiliary group than in the nonauxiliary group at 4 and 8 weeks, respectively. Conclusions: The auxiliary device improved the mechanical retention force without the need to increase miniscrew length or diameter. This may enable the safe use of miniscrews in difficult areas.

Publisher

The Angle Orthodontist (EH Angle Education & Research Foundation)

Subject

Orthodontics

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3