Patient compliance and orthodontic treatment efficacy of Planas functional appliances with TheraMon microsensors

Author:

Charavet Carole1,Le Gall Michel2,Albert Adelin3,Bruwier Annick4,Leroy Sophie5

Affiliation:

1. Researcher and Lecturer, Department of Dentofacial Orthopedics and Orthodontics, Faculty of Medicine, University of Liege, Liege, Belgium.

2. Chairman and Director, Orthodontic Education Program, Department of Dentofacial Orthopedics and Orthodontics, Faculty of Medicine, University of Marseille, Marseille, France.

3. Professor Emeritus, Biostatistics and Medico-Economic Information Department, University Hospital of Liège, University of Liege, Liege, Belgium.

4. Lecturer, Department of Dentofacial Orthopedics and Orthodontics, Faculty of Medicine, University of Liege, Liege, Belgium.

5. Orthodontist, Private practice, Liege, Belgium.

Abstract

ABSTRACT Objectives: To assess patient compliance and treatment efficacy of preventive expansion treatment with removable Planas functional appliances using an integrated microsensor. Materials and Methods: Wear time (WT) and behavior of 69 patients undergoing treatment with Planas functional appliances were assessed and analysed using TheraMon microsensors (Gschladt, Hargelsberg, Austria). Patients were followed up for a period of 9 months, and visits were made every 3 months to download WT data from the microsensor and to assess wearing behavior. From individual WT graphs,10 parameters were derived to characterize compliance for each patient. Treatment efficacy was measured by eight parameters determining the level of expansion after 9 months of treatment. Results: Patients wore their device on average 15.8 ± 5.2 h/d. WT was unrelated to age and gender, but it was positively influenced by patient habits when keeping appliances during eating, sports, care and handling. Treatment efficacy in terms of intercanine and intermolar expansion was 4.4 ± 1.9 mm and 4.6 ± 2.0 mm for the maxilla, and 5.3 ± 2.0 mm and 4.7 ± 2.3 mm for the mandible, respectively. Efficacy was negatively affected by poor compliance (WT < 9 h/d) and by high variability of within-subject WT recordings. Conclusions: Perfect compliance is not necessary to achieve treatment success, but patients should exhibit sufficient wear time to allow maxillary expansion to occur. The TheraMon microsensor offers a new perspective and aid to individualize treatment prescriptions.

Publisher

The Angle Orthodontist (EH Angle Education & Research Foundation)

Subject

Orthodontics

Cited by 16 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3