The effect of water storage on the bending properties of esthetic, fiber-reinforced composite orthodontic archwires

Author:

Chang Ju-Han1,Berzins David W.2,Pruszynski Jessica E.3,Ballard Richard W.4

Affiliation:

1. Orthodontic Resident, Department of Developmental Sciences, Marquette University, Milwaukee, Wis

2. Associate Professor, General Dental Sciences, Marquette University, Milwaukee, Wis

3. Assistant Professor, Division of Biostatistics, Medical College of Wisconsin, Milwaukee, Wis

4. Assistant Professor, Department of Orthodontics & Dentofacial Orthopedics, Louisiana State University Health Sciences Center School of Dentistry, New Orleans, La

Abstract

ABSTRACT Objective: To study the effect of water storage on the bending properties of fiber-reinforced composite archwires and compare it to nickel-titanium (NiTi), stainless steel (SS), and beta-titanium archwires. Materials and Methods: Align A, B, and C and TorQ A and B composite wires from BioMers Products, 0.014-, 0.016, and 0.018-inch, and 0.019 × 0.025-inch NiTi, 0.016-inch SS, and 0.019 × 0.025-inch beta-titanium archwires were tested (n  =  10/type/size/condition). A 20-mm segment was cut from each end of the archwire; one end was then stored in water at 37°C for 30 days, while the other was stored dry. The segments were tested using three-point bending to a maximum deflection of 3.1 mm with force monitored during loading (activation) and unloading (deactivation). Statistical analysis was completed via two-way analysis of variance with wire and condition (dry and water-stored) as factors. Results: In terms of stiffness and force delivery during activation, in general: beta-titanium was > TorQ B > TorQ A > 0.019 × 0.025-inch NiTi and 0.016-inch SS > Align C > 0.018-inch NiTi > Align B > 0.016-inch NiTi > Align A > 0.014-inch NiTi. Water exposure was detrimental to the larger translucent wires (Align B and C, TorQ A and B) because they were more likely to craze during bending, resulting in decreased forces applied at a given deflection. Align A and the alloy wires were not significantly (P > .05) affected by water storage. Overall, the alloy wires possessed more consistent force values compared to the composite wires. Conclusion: Environmental conditions are more likely to affect fiber-reinforced composite archwires compared to alloy wires.

Publisher

The Angle Orthodontist (EH Angle Education & Research Foundation)

Subject

Orthodontics

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3