Author:
Withayanukonkij Wisama,Chanmanee Pannapat,Promsawat Methee,Viteporn Smorntree,Leethanakul Chidchanok
Abstract
ABSTRACT
Objectives
To compare changes in maxillary molar root resorption, intrusion amount, dentoskeletal measures, and maximum bite force (MBF) between clear aligners (CA) and fixed appliances with miniscrew (FM) during molar intrusion.
Materials and Methods
Forty adults with anterior open bite were randomized into either CA or FM groups. Lateral cephalograms, cone-beam computed tomography (CBCT), and MBF were collected at pretreatment (T0) and 6 months of treatment (T1). Maxillary molar intrusion in FM were intruded by nickel-titanium (NiTi) closed-coil spring delivered force (150 grams/side) while clear aligners combined with squeezing exercise were performed in CA. Parametric tests were used for statistical analysis.
Results
After 6 months of treatment, significant root resorption of 0.21–0.24 mm in CA and 0.38–0.47 mm in FM were found while maxillary molars were intruded 0.68 and 1.49 mm in CA and FM, respectively. CA showed significant less root resorption and intrusion than FM. Overbite, bite closing, and MBF increased significantly. CA showed significantly less overbite and SN-MP changes but more MBF increase than FM. MBF in CA was correlated with the amount of maxillary molar intrusion (r = 0.736, P < .05).
Conclusions
Maxillary molar intrusion and root resorption in CA were half the amount in FM in 6 months. The amount of maxillary molar root resorption was one-third of the intrusion distance. CA displayed less overbite increase and bite closing but more MBF increase than FM. MBF in CA was positively correlated with the molar intrusion amount.
Publisher
The Angle Orthodontist (EH Angle Education & Research Foundation)
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献