Author:
Johal Ama,Bourauel Christoph,Moghanchi Samir,Dickerson Terry,Gaudin Paul,Elliott Emma Louise
Abstract
ABSTRACT
Objectives
To test a new concept in bracket design—the tip and torque adjustable bracket (TTAB)—to identify its integral ability to change both tip and torque.
Materials and Methods
The newly designed TTAB underwent independent testing using the orthodontic measurement and simulation system. The TTAB incorporated Roth tip and torque prescription values, with the unique quality of the bracket to enhance or reduce the innate prescribed values of tip (by either +10° or −10°) and torque (by either +7.5° or −7.5°). The TTAB was tested using both the incorporated standard Roth prescription on the rate of canine retraction (sliding mechanics), using 0.018-inch stainless-steel (SS) arch wire, and with alteration of tip values (−10° and +10°). Similarly, frictional measurements and torque evaluations using 0.019 × 0.025-inch SS arch wire were undertaken with the standard prescription and altered torque (+7.5° and −7.5°). In addition, a number of control investigations were performed. Differences were analyzed using analysis of variance.
Results
The rate of observed tooth movement for the TTAB with its prescribed baseline values was comparable to that of the control brackets. Importantly, the alteration of TTAB tip to −10° and +10° significantly (P < .001) increased and reduced, respectively, the rates of canine retraction. In the alteration of torque, at +7.5° and −7.5°, the bracket delivered a moment of +9.3 (2.8) Nmm and −11.9 (3.8) Nmm, respectively, to the lateral incisor (P < .001).
Conclusions
This in vitro study demonstrates a new concept in preadjusted edgewise bracket design, offering adjustable tip and torque, with the potential for expanded clinical scope.
Publisher
The Angle Orthodontist (EH Angle Education & Research Foundation)
Reference21 articles.
1. Andrews
LF.
The straight-wire appliance.
Brit J Orthod.
1979;
6:
125–
143.
2. McLaughlin
RP,
Bennett,
JC.
The transition from standard edgewise to preadjusted appliance systems.
J Clin Orthod.
1989;
23:
142–
153.
3. Morina
E,
Eliades
T,
Pandis
N,
Jäger
A,
Bourauel
C.
Torque expression of self-ligating brackets compared with conventional metallic, ceramic, and plastic brackets.
Eur J Orthod.
2008;
30:
233–
238.
4. Sifakakis
I,
Pandis
N,
Makou
M,
Eliades
T,
Katsaros
C,
Bourauel
C.
Torque expression of 0.018 and 0.022 inch conventional brackets. Eur J Orthod.
2012;
10.1093/ejo/cjs041
5. Burstone
CJ,
Koenig
HA.
Force systems from an ideal arch.
Am J Orthod.
1974;
65:
270–
289.
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献