Can modifying shielding, field of view, and exposure settings make the effective dose of a cone-beam computed tomography comparable to traditional radiographs used for orthodontic diagnosis?

Author:

Ting Stephanie,Attaia Diana,Johnson K. Brandon,Kossa Samer Shoukry,Friedland Bernard,Allareddy Veerasathpurush,Masoud Mohamed I.

Abstract

ABSTRACT Objectives To analyze the effect of changes in exposure settings, field of view (FOV), and shielding on radiation to an adult and child phantom from cone-beam computed tomography (CBCT) imaging compared to panoramic and lateral cephalometric radiographs. Materials and Methods The effective dose to an adult and child anthropomorphic phantom by the CS 9300 using various scan protocols was recorded. Absorbed radiation was measured with optically stimulated luminescence dosimeters and effective dose calculated using 2007 International Commission on Radiological Protection tissue weighting factors. Scan protocols included different FOVs, voxel sizes, and standard versus low-dose protocols. Radiation shielding was used when it did not interfere with FOV. Panoramic and lateral cephalometric radiographs were taken with the Orthophos SL. Results Even with shielding, smaller FOVs, and increased voxel sizes, the effective dose of standard CBCT scans was higher than panoramic and lateral cephalometric radiographs. A shielded limited FOV standard scan combined with a lateral cephalometric radiograph resulted in a lower dose (P < .001) than a full FOV standard scan. Low-dose shielded scans resulted in significant dose reductions to the adult (P < .05) and child (P < .001) phantoms compared to the respective panoramic and lateral cephalometric radiographs combined. Image quality analysis was not possible with radiation equivalent phantoms. Conclusions Unlike standard CBCTs, shielded low-dose CBCT protocols in the CS 9300 have lower effective doses than conventional radiographs for adult and child phantoms. If high resolution and cranial base visualization are necessary, combining a shielded LFOV standard exposure with a cephalometric radiograph is recommended.

Publisher

The Angle Orthodontist (EH Angle Education & Research Foundation)

Subject

Orthodontics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3