Reliability of the integrated radiograph-photograph method to obtain natural head position in cephalometric diagnosis

Author:

Dvortsin Dima P.1,Ye Qingsong2,Pruim Gerard J.3,Dijkstra Pieter U.4,Ren Yijin5

Affiliation:

1. Resident, Department of Orthodontics, University Medical Centre Groningen, University of Groningen, The Netherlands

2. PhD Candidate, Department of Orthodontics, University Medical Centre Groningen, University of Groningen, The Netherlands; Department of Orthodontics, West China College of Stomatology, Sichuan University, China

3. Instructor, Department of Orthodontics, University Medical Centre Groningen, University of Groningen, The Netherlands

4. Professor, Department of Oral and Maxillofacial Surgery, University Medical Centre Groningen, University of Groningen, The Netherlands

5. Professor and Chair, Department of Orthodontics, University Medical Centre Groningen, University of Groningen, The Netherlands

Abstract

Abstract Objective: To introduce a simple and reliable method to reorient lateral radiographs to the natural head position (NHP) according to standardized photographs made at NHP. Material and Methods: The study has two parts. In the first part, 45 patients were randomly selected from a patient cohort. Photographs (at NHP) and cephalograms from each patient were taken and assessed in two sessions by two observers. The time between the first and the second session was 5 weeks. The repeatability of profile measurements on cephalograms compared with standardized photographs of the same patient was determined; in the second part, the repeatability of three superimposing protocols (ie, the soft tissue N/subnasale line [V-line], the esthetic line [E-line], and a proposed nose best fit line [N-line]) was compared for the reorientation of the cephalogram according to the photographs made at the NHP. Results: Our results showed that the integration of radiographs and photographs is an objective and reliable method to obtain NHP in lateral cephalograms. The N-line is a reproducible and stable reference line for the reorientation of radiographs to obtain NHP. Conclusion: Reorientation of radiographs according to standardized photographs made at the NHP is a reliable and objective method to standardize the radiographs at the NHP for cephalometric analysis. The N-line is a reproducible and stable reference line for the reorientation. It is preferred over the V-line or even E-line, especially when the radiographs and photographs are taken at different sessions or at different treatment stages.

Publisher

The Angle Orthodontist (EH Angle Education & Research Foundation)

Subject

Orthodontics

Cited by 18 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3