Measurement accuracy with a new dental panoramic radiographic technique based on tomosynthesis

Author:

Kitai Noriyuki1,Mukai Yousuke2,Murabayashi Manabu3,Kawabata Atsushi4,Washino Kaei5,Matsuoka Masato6,Shimizu Ichirou6,Katsumata Akitoshi7

Affiliation:

1. Professor and Chair, Department of Orthodontics, School of Dentistry, Asahi University, Gifu, Japan.

2. Assistant Professor, Department of Orthodontics, School of Dentistry, Asahi University, Gifu, Japan.

3. Graduate student, Department of Orthodontics, School of Dentistry, Asahi University, Gifu, Japan.

4. Senior Lecturer, Department of Orthodontics, School of Dentistry, Asahi University, Gifu, Japan.

5. Professor, Gifu Shotoku Gakuen University Junior College, Gifu, Japan.

6. Assistant Professor, Department of Oral Radiology, School of Dentistry, Asahi University, Gifu, Japan.

7. Professor and Chair, Department of Oral Radiology, School of Dentistry, Asahi University, Gifu, Japan.

Abstract

Abstract Objective: To investigate measurement errors and head positioning effects on radiographs made with new dental panoramic radiograph equipment that uses tomosynthesis. Materials and Methods: Radiographic images of a simulated human head or phantom were made at standard head positions using the new dental panoramic radiograph equipment. Measurement errors were evaluated by comparing with the true values. The phantom was also radiographed at various alternative head positions. Significant differences between measurement values at standard and alternative head positions were evaluated. Magnification ratios of the dimensions at standard and alternative head positions were calculated. Results: The measurement errors were small for all dimensions. On the measurements at 4-mm displacement positions, no dimension was significantly different from the standard value, and all dimensions were within ±5% of the standard values. At 12-mm displacement positions, the magnification ratios for tooth length and mandibular ramus height were within ±5% of the standard values, but those for dental arch width, mandibular width, and mandibular body length were beyond ±5% of the standard values. Conclusions: Measurement errors on radiographs made using the new panoramic radiograph equipment were small in any direction. At 4-mm head displacement positions, no head positioning effect on the measurements was found. At 12-mm head displacement positions, the measurements for vertical dimensions were little affected by head positioning, while those for lateral and anteroposterior dimensions were strongly affected.

Publisher

The Angle Orthodontist (EH Angle Education & Research Foundation)

Subject

Orthodontics

Cited by 21 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3