Assesment of the temperature loading influence on crack resistance of a tank with a semi-eliptical crack

Author:

Pyskunov SerhiiORCID,Goncharenko MarynaORCID,Shkryl OleksiiORCID

Abstract

Reservoir parks are the main place of storage of petroleum products. There has been a tendency transition to the use of larger tanks in recent years, which is economically justified. However, it is leads to fire risk increase to accumulate large quantities of petroleum products. Tank fire is one of the most dangerous emergency event, which can lead not only to significant material damage but also to ecological human losses in case of spreading of fire to other tanks. To ensure safety and test the bearing capacity in these conditions determination of the stress-strain state in such tanks must be performed taking into account the temperature load. If there is an initial crack in the tank wall the assessment of crack resistance should be performed. In a previous work the authors determined the stress intensity factor (SIF) distribution along the semi-elliptical crack front in the RVS-5000 tank under hydrostatic pressure. The estimation of a stress-strain state of a steel vertical tank with an initial semi-elliptical crack under the thermal loading is performed in this article. It is suppoused that the part of wall of the tank, located closest to the fire epicenter, is heated unevenly in height: from 300 degrees at the top to 200 degrees at the bottom. On the other part of the tank the temperature reaches 70 degrees. The temperature within wall thickness is considered constant. Given the asymmetric nature of the temperature distribution, a discrete model was developed for the entire tank. After determining the  stress-strained state in the whole tank under  hydrostatic pressure and temperature load, a fragment with a semi-elliptical crack was calculated separately. The stresses determined from the calculation of the whole tank are used like an external load, applied on fragment boundaries. The difference of results of direct and energetic method of SIF calculation are in the range of 5%.  Taking into account the temperature loading leads to an increase in the SIF values by about 20 % in comparison to the results of the calculation only under hydrostatic pressure.

Publisher

Kyiv National University of Construction and Architecture

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3